A simulated detector records mean counts in one-minute windows beginning at the stated times. The expected source signal halves every fixed interval. Background is 20 counts/min throughout; detector geometry and efficiency remain unchanged.
Example data
These are simulated records. Equal counting-window lengths and an independent background estimate are essential. Repeated/longer suitable counts help reveal statistical scatter.
Plot and check the data
1. Find half-life after correcting background counts
A simulated detector records mean counts in one-minute windows beginning at the stated times. The expected source signal halves every fixed interval. Background is 20 counts/min throughout; detector geometry and efficiency remain unchanged.
Plot mean detected count rate against window start time. Draw a smooth curve through or close to the data.[5 marks]
Results Example data
Window start time / min
Mean detected count rate / counts/min
0
660
2
340
4
180
6
100
8
60
1 · Axes, labels and scales
Put Window start time / min (the independent variable) on the x-axis and Mean detected count rate / counts/min on the y-axis. This grid is 8 big squares across and 10 up; each big square has 5 × 5 small squares.
Set your scales, then tap the grid to plot each point.
Keyboard and screen-reader entry
Values are placed using the scale you set, so a wrong scale still gives a wrong graph – just like on paper.
Stuck on the scale?
Subtract the same background before looking for halvings. A detector registers only some of the decays.
Interpret the evidence
Use numbers and units from the results. Graph feedback checks plotting conventions; interpretation is self-assessed against the criteria.
6 marks
Data Gym
Use the evidence, then compare your reasoning
Find the corrected source count rates at 0,2 and 4 minutes and use them to determine half-life. Predict total count rate at 10 minutes. Explain why raw readings do not halve exactly and why the corrected count rate is not automatically activity in becquerels.
(6)
Answer using the evidence, then reveal the guidance. Tick one mark for each criterion met; equivalent scientific explanations are acceptable.
Total for this question: 6 marks
Reference graph and worked reasoning
Reference graph for this example. Compare axes, units, scales, points and the requested line; use the table for precise values.
Using 660/2=330 as a raw target would not isolate the source half-life; the correct source levels are 640,320,160,80,40.
The source contribution continues to decrease towards zero while the expected total approaches the 20 counts/min background level.