Use thermistor data to test a temperature claim

Unit 1 · 4WPH1 · Specification 2.10, 2.11, 2.13

A thermistor is placed in a water bath at different temperatures. Its resistance is read after the thermistor reaches the bath temperature. Resistance values are shown in ohms, with a small measuring current to limit self-heating.

Example data

These values model a thermistor whose resistance decreases as temperature rises. Keep immersion depth and measuring conditions consistent; allow time to reach each temperature. Do not extrapolate to every temperature or every type of sensor.

Plot and check the data

1. Use thermistor data to test a temperature claim

A thermistor is placed in a water bath at different temperatures. Its resistance is read after the thermistor reaches the bath temperature. Resistance values are shown in ohms, with a small measuring current to limit self-heating.

Plot resistance against temperature. Draw a smooth curve through or close to the data. [5 marks]

Results Example data
Temperature / °CResistance / Ω
1020000
2012000
307500
404800
503200
602200
1 · Axes, labels and scales

Put Temperature / °C (the independent variable) on the x-axis and Resistance / Ω on the y-axis. This grid is 8 big squares across and 10 up; each big square has 5 × 5 small squares.

x-axis
y-axis
x-axis labely-axis label

Set your scales, then tap the grid to plot each point.

Keyboard and screen-reader entry

Values are placed using the scale you set, so a wrong scale still gives a wrong graph – just like on paper.

Stuck on the scale?

A trend can be decreasing without a constant gradient or a fixed percentage change.

Interpret the evidence

Use numbers and units from the results. Graph feedback checks plotting conventions; interpretation is self-assessed against the criteria.

5 marks

Data Gym

Use the evidence, then compare your reasoning

Evaluate the claim “resistance falls by the same amount for every 10 °C increase”. Quote two intervals. Find the current at 20 °C with 6.0 V across the thermistor. Predict the direction of current change at 40 °C if the same voltage is maintained, and explain a control needed.

(5)

Answer using the evidence, then reveal the guidance. Tick one mark for each criterion met; equivalent scientific explanations are acceptable.

Total for this question: 5 marks

Reference graph and worked reasoning
Resistance against Temperature. Thermistor: (10, 20000), (20, 12000), (30, 7500), (40, 4800), (50, 3200), (60, 2200). Values and units are also in the results table.0102030405060708002000400060008000100001200014000160001800020000Temperature / °CResistance / Ω
Reference graph for this example. Compare axes, units, scales, points and the requested line; use the table for precise values.
  1. The downward curve supports decreasing resistance over the tested interval, not a constant decrease per degree.
  2. 6.0/4800=0.00125 A; this is 2.5 times the current at 20 °C. A bath reading represents the thermistor only after thermal equilibration.

Related lessons

Return to the course