A model electric motor transfers a constant fraction of its input energy to useful mechanical work. The remaining energy is transferred to the surroundings by heating and sound. The graph records useful output for several input energies.
Example data
Assume the efficiency stays fixed. Actual efficiency can change with load or operating conditions.
Plot and check the data
1. Check useful energy and the missing output
A model electric motor transfers a constant fraction of its input energy to useful mechanical work. The remaining energy is transferred to the surroundings by heating and sound. The graph records useful output for several input energies.
Plot useful output energy against input energy. Draw a straight line of best fit.[5 marks]
Results Example data
Input energy / J
Useful output energy / J
0
0
100
40
200
80
300
120
400
160
500
200
1 · Axes, labels and scales
Put Input energy / J (the independent variable) on the x-axis and Useful output energy / J on the y-axis. This grid is 8 big squares across and 10 up; each big square has 5 × 5 small squares.
Set your scales, then tap the grid to plot each point.
Keyboard and screen-reader entry
Values are placed using the scale you set, so a wrong scale still gives a wrong graph – just like on paper.
Stuck on the scale?
Useful output is not the entire output. Account for both useful and unwanted transfers.
Interpret the evidence
Use numbers and units from the results. Graph feedback checks plotting conventions; interpretation is self-assessed against the criteria.
5 marks
Data Gym
Use the evidence, then compare your reasoning
Use two readings to find efficiency and test whether it is constant. Calculate the unwanted output for a 500 J input. For a Sankey diagram of that case, give the useful and unwanted arrow widths if the input arrow is 10 mm wide. Explain why a lower useful output does not violate energy conservation.
(5)
Answer using the evidence, then reveal the guidance. Tick one mark for each criterion met; equivalent scientific explanations are acceptable.
Total for this question: 5 marks
Reference graph and worked reasoning
Reference graph for this example. Compare axes, units, scales, points and the requested line; use the table for precise values.
Efficiency as a fraction is 0.40; expressed as a percentage it is 40%.
The Sankey output widths add to the input width:4+6=10 mm. Unwanted transfer is not destroyed energy.