Compare penetration using corrected detector data

Unit 2 · 4WPH2 · Specification 8.5, 8.6, 8.9

Two simulated radiation signals are compared with increasing aluminium thickness. Background has already been subtracted. Each source–detector geometry is fixed; both signals begin at 100 counts/s without the added absorber.

Example data

Use these simulated records to interpret a penetration investigation.

Plot and check the data

1. Compare penetration using corrected detector data

Two simulated radiation signals are compared with increasing aluminium thickness. Background has already been subtracted. Each source–detector geometry is fixed; both signals begin at 100 counts/s without the added absorber.

Plot corrected count rate against aluminium thickness. Join consecutive points with straight lines. [6 marks]

Results Example data
Aluminium thickness / cmBeta model: Corrected count rate / counts/sGamma model: Corrected count rate / counts/s
0100100
0.14094
0.21088
0.3183
0.4078
0.5073
1 · Axes, labels and scales

Put Aluminium thickness / cm (the independent variable) on the x-axis and Corrected count rate / counts/s on the y-axis. This grid is 8 big squares across and 10 up; each big square has 5 × 5 small squares.

x-axis
y-axis
x-axis labely-axis label

Set your scales, then tap the grid to plot each point.

Keyboard and screen-reader entry

Values are placed using the scale you set, so a wrong scale still gives a wrong graph – just like on paper.

Key
Stuck on the scale?

Compare the two changes at the same thickness. These signals do not establish a universal stopping thickness.

Interpret the evidence

Use numbers and units from the results. Graph feedback checks plotting conventions; interpretation is self-assessed against the criteria.

5 marks

Data Gym

Use the evidence, then compare your reasoning

Compare attenuation at 0.20 cm using numerical evidence. State which signal is more penetrating in this model and explain why a zero corrected beta value does not prove a source has stopped decaying. Give a control anda limit on using these results to identify unknown radiation.

(5)

Answer using the evidence, then reveal the guidance. Tick one mark for each criterion met; equivalent scientific explanations are acceptable.

Total for this question: 5 marks

Reference graph and worked reasoning
Corrected count rate against Aluminium thickness. Beta model: (0, 100), (0.1, 40), (0.2, 10), (0.3, 1), (0.4, 0), (0.5, 0); Gamma model: (0, 100), (0.1, 94), (0.2, 88), (0.3, 83), (0.4, 78), (0.5, 73). Values and units are also in the results table.0.00.10.20.30.40.50.60.70.80102030405060708090100Beta modelGamma modelAluminium thickness / cmCorrected count rate / counts/s
Reference graph for this example. Compare axes, units, scales, points and the requested line; use the table for precise values.
  1. A smaller count rate beyond an absorber can mean greater absorption or scattering, not a smaller intrinsic activity of the same source.
  2. Straight segments connect sampled thicknesses for comparison; they do not claim a universal linear attenuation law.

Related lessons

Return to the course