Two simulated radiation signals are compared with increasing aluminium thickness. Background has already been subtracted. Each source–detector geometry is fixed; both signals begin at 100 counts/s without the added absorber.
Example data
Use these simulated records to interpret a penetration investigation.
Plot and check the data
1. Compare penetration using corrected detector data
Two simulated radiation signals are compared with increasing aluminium thickness. Background has already been subtracted. Each source–detector geometry is fixed; both signals begin at 100 counts/s without the added absorber.
Plot corrected count rate against aluminium thickness. Join consecutive points with straight lines.[6 marks]
Results Example data
Aluminium thickness / cm
Beta model: Corrected count rate / counts/s
Gamma model: Corrected count rate / counts/s
0
100
100
0.1
40
94
0.2
10
88
0.3
1
83
0.4
0
78
0.5
0
73
1 · Axes, labels and scales
Put Aluminium thickness / cm (the independent variable) on the x-axis and Corrected count rate / counts/s on the y-axis. This grid is 8 big squares across and 10 up; each big square has 5 × 5 small squares.
Set your scales, then tap the grid to plot each point.
Keyboard and screen-reader entry
Values are placed using the scale you set, so a wrong scale still gives a wrong graph – just like on paper.
Stuck on the scale?
Compare the two changes at the same thickness. These signals do not establish a universal stopping thickness.
Interpret the evidence
Use numbers and units from the results. Graph feedback checks plotting conventions; interpretation is self-assessed against the criteria.
5 marks
Data Gym
Use the evidence, then compare your reasoning
Compare attenuation at 0.20 cm using numerical evidence. State which signal is more penetrating in this model and explain why a zero corrected beta value does not prove a source has stopped decaying. Give a control anda limit on using these results to identify unknown radiation.
(5)
Answer using the evidence, then reveal the guidance. Tick one mark for each criterion met; equivalent scientific explanations are acceptable.
Total for this question: 5 marks
Reference graph and worked reasoning
Reference graph for this example. Compare axes, units, scales, points and the requested line; use the table for precise values.
A smaller count rate beyond an absorber can mean greater absorption or scattering, not a smaller intrinsic activity of the same source.
Straight segments connect sampled thicknesses for comparison; they do not claim a universal linear attenuation law.