Unit 1 · 4WPH1 · Specification 2.7, 2.13, 2.17, 2.18
Two resistors of 10 Ω and 20 Ω are connected in parallel to a low-voltage supply. Their temperatures and resistances stay constant. The supply maintains the stated voltage across both branches.
Example data
Straight segments join the observed values; constant resistance also predicts straight-line relationships here. Use only low-voltage, current-limited equipment.
Plot and check the data
1. Check charge conservation in a parallel circuit
Two resistors of 10 Ω and 20 Ω are connected in parallel to a low-voltage supply. Their temperatures and resistances stay constant. The supply maintains the stated voltage across both branches.
Plot current against supply voltage. Join consecutive points with straight lines.[6 marks]
Results Example data
Supply voltage / V
Supply: Current / A
10 Ω branch: Current / A
20 Ω branch: Current / A
0
0
0
0
2
0.3
0.2
0.1
4
0.6
0.4
0.2
6
0.9
0.6
0.3
1 · Axes, labels and scales
Put Supply voltage / V (the independent variable) on the x-axis and Current / A on the y-axis. This grid is 8 big squares across and 10 up; each big square has 5 × 5 small squares.
Set your scales, then tap the grid to plot each point.
Keyboard and screen-reader entry
Values are placed using the scale you set, so a wrong scale still gives a wrong graph – just like on paper.
Stuck on the scale?
At each voltage add the branch currents. Each branch has the full supply voltage, not half of it.
Interpret the evidence
Use numbers and units from the results. Graph feedback checks plotting conventions; interpretation is self-assessed against the criteria.
5 marks
Data Gym
Use the evidence, then compare your reasoning
Use the 6 V readings to check current conservation and determine both resistances. Explain why the branch currents differ. Predict both the supply current and the remaining branch current if the 20 Ω branch is disconnected while the voltage remains 6 V.
(5)
Answer using the evidence, then reveal the guidance. Tick one mark for each criterion met; equivalent scientific explanations are acceptable.
Total for this question: 5 marks
Reference graph and worked reasoning
Reference graph for this example. Compare axes, units, scales, points and the requested line; use the table for precise values.
At 2 V:0.20+0.10=0.30 A; at 4 V:0.40+0.20=0.60 A. Conservation is supported at every supplied voltage.
Independent operation relies on maintaining the supply voltage. A supply whose voltage falls under load would need separate measurements.