Learning goals
- Plan a source–absorber–detector comparison or a simulation.
- Process repeated counts and background correctly.
- Draw conclusions limited by detector sensitivity and random variation.
Purpose and apparatus
The question is how different absorbers affect radiation reaching a detector. Use a suitable detector and counter, an absorber holder and measured sheets of paper, aluminium and lead. The detector must be sensitive to the radiation being tested; a thick detector window can stop alpha before it is detected.
A school source investigation is a supervised demonstration using approved sealed sources and the school’s procedures. Sources stay in their holders, exposure time is minimised, handling uses the designated tool and unused sources return to secure storage. A simulation allows the same variables and analysis without a real source.
Control the comparison
Fix the source and detector securely, measure their separation and keep it unchanged. Place absorbers between them without moving either. For alpha, the air gap must be short enough for some radiation to reach the detector initially. Record material and thickness as independent variables; count rateThe number of radiation events registered by a detector per unit time. is the dependent variable.
Measure background with the source removed to storage. Then measure the source with no absorber for a fixed interval, such as 60 s. Repeat at least three times. Insert each absorber in turn and repeat using the same intervals, detector settings, alignment and separation. For thickness comparisons use measured increments of the same material.
Process an example
Background counts are 28, 32 and 30 in three 60 s trials: total 90 in 180 s, or 0.50 counts/s. With a beta-like source and no absorber, counts 628, 642 and 620 total 1890 in 180 s, or 10.50 counts/s. Corrected source rate = 10.50 − 0.50 = 10.00 counts/s.
With paper, total 1800 counts in 180 s gives a corrected 9.50 counts/s. With 3 mm aluminium, total 96 gives 0.533 counts/s measured, or about 0.03 counts/s after subtraction. That small excess is compatible with background fluctuation; it is not convincing evidence of beta transmission.
Interpret and evaluate
Plot corrected count rateThe number of radiation events registered by a detector per unit time. against absorber thickness with labelled units. Alpha should be strongly reduced by paper; beta by suitable aluminium; gamma is reduced progressively by thick dense absorbers. Compare changes against the scatter of repeated counts.
Longer total counting time and repeats reduce relative random uncertaintyThe estimated range around a measured value within which the true value is expected to lie.. They do not fix a detector that cannot detect the radiation, changed geometry, an incorrectly measured thickness or an unrepresentative background. A background-level reading means no clear source contribution was detected in this setup, not proof that absolutely no radiation exists.
Equations
- corrected count rate = measured source-plus-background rate − background rate
Common misconceptions
- Do not subtract raw background counts collected over a different duration.
- A calculated small negative corrected rate indicates measurement variation around zero, not negative radiation.
Separate absorber effects from background counts
Change aluminium thickness and background, then distinguish corrected radiation signals from total registered rates.
What you see
- Labelled diagrams and numerical outputs describe the same selected state.
How to use it
- Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
- Reset restores every model control to its initial value. Nothing is saved.
What it shows
- Absorption can reduce radiation reaching a detector without changing the source activity. Add background to obtain the total registered rate; subtract the same matched background to recover the corrected signal. These curves illustrate different penetration in this setup. A real background-level result is limited by counting variation and detector sensitivity.
Limits of the model
- Three separate signals each begin at 100 corrected counts/s with no absorber. Geometry and detector sensitivity stay fixed; the detector can register the alpha signal before adding the absorber. Equal initial count rates do not establish equal source activities.
- Curves join the recorded points; they are not general stopping laws. Radiation energy, absorber and detector affect real results. Background is known exactly here; counting fluctuations are not simulated.
Controls
A zero corrected curve value represents no detected source contribution in this model. It does not prove zero source activity or safe exposure. Background correction does not repair an unsuitable detector or changed geometry.
Predict, change and explain
At 1 mm aluminium, compare the corrected alpha, beta and gamma rates. Increase background alone: predict which totals change and whether the corrected curves should change. Explain why a zero corrected model value does not mean the source has stopped decaying.
Connect the outcome to the Physics
Absorption can reduce radiation reaching a detector without changing the source activity. Add background to obtain the total registered rate; subtract the same matched background to recover the corrected signal. These curves illustrate different penetration in this setup. A real background-level result is limited by counting variation and detector sensitivity.