Learning goals
- Calculate forward and backward through half-lives.
- Use graphs for non-integer halving intervals.
- Correct measured background before comparing count-rate fractions.
Forward calculation
A source starts at 800 Bq and has a half-lifeThe time for the activity or number of undecayed nuclei of an isotope to decrease to half its initial value. of 2 h. After 6 h the number of half-lives is n = 6 ÷ 2 = 3. Halve three times: 800 → 400 → 200 → 100 Bq. Equivalently, 800 × (1/2)³ = 100 Bq.
Only 1/8 = 12.5% of the original parent nucleusThe dense central region of an atom containing protons and neutrons, except hydrogen-1 which has no neutron. remain on average; 87.5% have decayed. Do not confuse the remaining fraction with the fraction that has decayed. These statements refer to parent nuclei, not the fraction of all material that disappears.
Work backwards
If the activityThe number of nuclear decays per unit time in a radioactive sample, measured in becquerels. is 100 Bq after 6 h and the half-lifeThe time for the activity or number of undecayed nuclei of an isotope to decrease to half its initial value. is 2 h, go backwards through three doublings: 100 → 200 → 400 → 800 Bq. If an activity falls from 960 to 120 Bq in 9 h, the ratio 120/960 = 1/8 shows three half-lives, so the half-life is 9 ÷ 3 = 3 h.
Graphical estimate
At 3 h on the 2 h half-lifeThe time for the activity or number of undecayed nuclei of an isotope to decrease to half its initial value. graph, trace vertically to the curve and horizontally to the activityThe number of nuclear decays per unit time in a radioactive sample, measured in becquerels. axis. Read about 280 Bq, with precisionThe closeness of repeated measured values to one another. limited by the graph. It is not 300 Bq: the midpoint of a time interval does not give the arithmetic midpoint of an exponential decrease.
Convert units before counting intervals: a 30 min half-life fits four times into 2 h = 120 min. A 160 Bq source would then have activity 160 ÷ 16 = 10 Bq.
Background correction example
A detector initially measures 42 counts/s including a 2 counts/s background. Later it measures 12 counts/s under the same geometry. Corrected rates are 40 and 10 counts/s, so the source contribution has fallen to one quarter: two half-lives have passed.
Halving the uncorrected total would give the wrong result. Keep detector efficiencyThe fraction of total energy input transferred usefully, also equal to useful power output divided by total power input., geometry and background assumptions explicit, and use repeated or sufficiently long counts to reduce random scatter.
Equations
- n = elapsed time ÷ half-life
- activity after n half-lives = initial activity × (1/2)ⁿ
Common misconceptions
- Three half-lives means divide by eight, not divide by three.
- Always state whether a percentage is the fraction remaining or the fraction already decayed.
Read a half-life curve without predicting individual decays
Change initial activity and half-life, then compare equal time intervals and remaining activity.
What you see
- Labelled diagrams and numerical outputs describe the same selected state.
How to use it
- Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
- Reset restores every model control to its initial value. Nothing is saved.
What it shows
- Each half-life halves the expected activity; it does not remove the same activity amount each time. Doubling initial activity scales the whole curve, while changing half-life changes its timescale. Actual decays and measurements fluctuate. A smooth trend cannot tell which individual nucleus decays next.
Limits of the model
- One radioactive component with a fixed half-life; daughter activity is excluded. Changing the half-life control selects a different model source, not an external way to alter a given isotope. The curve is a smooth expected trend, not a prediction of each random decay or detector count.
- Activity is the source decay rate in Bq, not a background-corrected detector count rate. No detector efficiency or exposure risk is modelled. Tiny non-zero results use standard form instead of rounding to zero.
Controls
The plotted expectation approaches zero; a small calculated result is not reported as exact zero. This curve does not predict the outcome of every measurement or the last decay in a finite sample.
Predict, change and explain
Start at 800 Bq with a 6 h half-life. Predict activity after 6, 12 and 18 h. Double only the initial activity, then restore it and double half-life. Explain why a reading close to zero would not prove that a source is inactive.
Connect the outcome to the Physics
Each half-life halves the expected activity; it does not remove the same activity amount each time. Doubling initial activity scales the whole curve, while changing half-life changes its timescale. Actual decays and measurements fluctuate. A smooth trend cannot tell which individual nucleus decays next.