8.13

Calculating half-life from data

Use repeated halving, or read a calibrated decay graph, to calculate remaining activity. Convert elapsed time and half-life to matching units first.

Recall for 8.13 · Exam questions for 8.13 · Data Gym · Logic Lab · Simulations · Reasoning about radioactivity and nuclear changes · Maths Clinic · Half-life and background correction · Find half-life after correcting background counts · Check a claim that a source has decayed away

Learning goals

  • Calculate forward and backward through half-lives.
  • Use graphs for non-integer halving intervals.
  • Correct measured background before comparing count-rate fractions.

Forward calculation

A source starts at 800 Bq and has a of 2 h. After 6 h the number of half-lives is n = 6 ÷ 2 = 3. Halve three times: 800 → 400 → 200 → 100 Bq. Equivalently, 800 × (1/2)³ = 100 Bq.

Only 1/8 = 12.5% of the original parent remain on average; 87.5% have decayed. Do not confuse the remaining fraction with the fraction that has decayed. These statements refer to parent nuclei, not the fraction of all material that disappears.

Three half-lives leave 100 Bq, or 12.5% of the original. Open full-size figure
100 Bq at 6 h, half-life 2 h: double three times to get 800 Bq at the start.

Work backwards

If the is 100 Bq after 6 h and the is 2 h, go backwards through three doublings: 100 → 200 → 400 → 800 Bq. If an activity falls from 960 to 120 Bq in 9 h, the ratio 120/960 = 1/8 shows three half-lives, so the half-life is 9 ÷ 3 = 3 h.

800 Bq with a 2 h half-life is about 280 Bq at 3 h: read the curve.

Graphical estimate

At 3 h on the 2 h graph, trace vertically to the curve and horizontally to the axis. Read about 280 Bq, with limited by the graph. It is not 300 Bq: the midpoint of a time interval does not give the arithmetic midpoint of an exponential decrease.

Convert units before counting intervals: a 30 min half-life fits four times into 2 h = 120 min. A 160 Bq source would then have activity 160 ÷ 16 = 10 Bq.

Subtract 2 counts/s from both: 40 to 10 counts/s is two half-lives.

Background correction example

A detector initially measures 42 counts/s including a 2 counts/s background. Later it measures 12 counts/s under the same geometry. Corrected rates are 40 and 10 counts/s, so the source contribution has fallen to one quarter: two half-lives have passed.

Halving the uncorrected total would give the wrong result. Keep detector , geometry and background assumptions explicit, and use repeated or sufficiently long counts to reduce random scatter.

Equations

  • n = elapsed time ÷ half-life
  • activity after n half-lives = initial activity × (1/2)ⁿ

Common misconceptions

  • Three half-lives means divide by eight, not divide by three.
  • Always state whether a percentage is the fraction remaining or the fraction already decayed.
Interactive model

Read a half-life curve without predicting individual decays

Change initial activity and half-life, then compare equal time intervals and remaining activity.

What you see
  • Labelled diagrams and numerical outputs describe the same selected state.
How to use it
  • Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
  • Reset restores every model control to its initial value. Nothing is saved.
What it shows
  • Each half-life halves the expected activity; it does not remove the same activity amount each time. Doubling initial activity scales the whole curve, while changing half-life changes its timescale. Actual decays and measurements fluctuate. A smooth trend cannot tell which individual nucleus decays next.
Limits of the model
  • One radioactive component with a fixed half-life; daughter activity is excluded. Changing the half-life control selects a different model source, not an external way to alter a given isotope. The curve is a smooth expected trend, not a prediction of each random decay or detector count.
  • Activity is the source decay rate in Bq, not a background-corrected detector count rate. No detector efficiency or exposure risk is modelled. Tiny non-zero results use standard form instead of rounding to zero.

Controls

800 Bq
6 h
12 h
Expected source activity against elapsed timeInitial activity 800 Bq, half-life 6 h. At 12 h the model activity is 200 Bq after 2 half-lives. The full curve projects 24 h; the dot marks the selected time. A smooth curve is not individual decay timing.Activity / Bq020040060080006121824Time / h
Initial activity 800 Bq, half-life 6 h. At 12 h the model activity is 200 Bq after 2 half-lives. The full curve projects 24 h; the dot marks the selected time. A smooth curve is not individual decay timing.
Expected source activity200 Bq
Elapsed half-lives2
Half-life6 h

The plotted expectation approaches zero; a small calculated result is not reported as exact zero. This curve does not predict the outcome of every measurement or the last decay in a finite sample.

Predict, change and explain

Start at 800 Bq with a 6 h half-life. Predict activity after 6, 12 and 18 h. Double only the initial activity, then restore it and double half-life. Explain why a reading close to zero would not prove that a source is inactive.

Connect the outcome to the Physics

Each half-life halves the expected activity; it does not remove the same activity amount each time. Doubling initial activity scales the whole curve, while changing half-life changes its timescale. Actual decays and measurements fluctuate. A smooth trend cannot tell which individual nucleus decays next.