Learning goals
- Define activity in Bq.
- Explain why the expected decay rate falls.
- Distinguish activity, remaining nuclei and measured count rate.
Why fewer decays occur later
Each unstable nucleusThe dense central region of an atom containing protons and neutrons, except hydrogen-1 which has no neutron. has a characteristic probability of decay per unit time. For the same isotopeOne of the forms of an element with the same proton number but a different neutron number. this probability does not increase as the nucleus gets older. When many nuclei remain, many can decay in the next second. Later, fewer undecayed nuclei remain, so the expected number of decays per second is smaller.
A smaller activityThe number of nuclear decays per unit time in a radioactive sample, measured in becquerels. does not mean each remaining nucleus has become less unstable. It means there are fewer nuclei of that radioactive parent available to decay. The daughter products may be stable or may themselves decay.
Activity is a rate, not a stock
A source activityThe number of nuclear decays per unit time in a radioactive sample, measured in becquerels. of 800 Bq means an average of about 800 nuclear decays per second at that time. It is not a statement that only 800 nucleusThe dense central region of an atom containing protons and neutrons, except hydrogen-1 which has no neutron. remain. A large population can have a low activity if each nucleus has a very small chance of decaying in one second.
For a large single-isotope sample, activity is proportional to the number of that isotopeOne of the forms of an element with the same proton number but a different neutron number.’s undecayed nuclei. If its remaining population falls to one quarter, its activity also falls to one quarter, provided no nuclei are being added.
A measured rate needs interpretation
For unchanged geometry and detector efficiencyThe fraction of total energy input transferred usefully, also equal to useful power output divided by total power input., a background-corrected count rateThe number of radiation events registered by a detector per unit time. can be proportional to source activityThe number of nuclear decays per unit time in a radioactive sample, measured in becquerels.. An example uses a fixed 5% detection fraction: activities 800, 400, 200 and 100 Bq give source count rates 40, 20, 10 and 5 counts/s.
With a constant background of 2 counts/s, measured totals would be 42, 22, 12 and 7 counts/s. Halve the corrected source contribution, not the total including background. Real detectors register different fractions.
Scope of the smooth decrease
An ideal smooth curve represents the expected behaviour of many nucleusThe dense central region of an atom containing protons and neutrons, except hydrogen-1 which has no neutron.. Individual short counts fluctuate randomly around it. A mixture containing radioactive daughters can have a more complicated total activityThe number of nuclear decays per unit time in a radioactive sample, measured in becquerels., so use the single-isotope assumption when interpreting a simple decay graph.
Equations
- 1 Bq = 1 decay per second
- fixed single-isotope conditions: activity ∝ number of undecayed parent nuclei
Common misconceptions
- Activity is not the number of nuclei that have already decayed.
- Moving a detector farther away reduces its count rate without changing the source activity.
Read a half-life curve without predicting individual decays
Change initial activity and half-life, then compare equal time intervals and remaining activity.
What you see
- Labelled diagrams and numerical outputs describe the same selected state.
How to use it
- Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
- Reset restores every model control to its initial value. Nothing is saved.
What it shows
- Each half-life halves the expected activity; it does not remove the same activity amount each time. Doubling initial activity scales the whole curve, while changing half-life changes its timescale. Actual decays and measurements fluctuate. A smooth trend cannot tell which individual nucleus decays next.
Limits of the model
- One radioactive component with a fixed half-life; daughter activity is excluded. Changing the half-life control selects a different model source, not an external way to alter a given isotope. The curve is a smooth expected trend, not a prediction of each random decay or detector count.
- Activity is the source decay rate in Bq, not a background-corrected detector count rate. No detector efficiency or exposure risk is modelled. Tiny non-zero results use standard form instead of rounding to zero.
Controls
The plotted expectation approaches zero; a small calculated result is not reported as exact zero. This curve does not predict the outcome of every measurement or the last decay in a finite sample.
Predict, change and explain
Start at 800 Bq with a 6 h half-life. Predict activity after 6, 12 and 18 h. Double only the initial activity, then restore it and double half-life. Explain why a reading close to zero would not prove that a source is inactive.
Connect the outcome to the Physics
Each half-life halves the expected activity; it does not remove the same activity amount each time. Doubling initial activity scales the whole curve, while changing half-life changes its timescale. Actual decays and measurements fluctuate. A smooth trend cannot tell which individual nucleus decays next.