Learning goals
- Describe primary, secondary and laminated core.
- Explain the chain from primary current to secondary voltage.
- Distinguish alternating operation from steady d.c.
Structure
The primary winding connects to an alternating supply. The secondary winding connects to the output circuit. Both are insulated conducting wire wound around a shared soft magnetic core, often laminated iron.
The windings are electrically separate in this simple transformerA device using electromagnetic induction between coils to change alternating voltage.: electric chargeA property of particles responsible for electrical interactions, measured in coulombs. does not jump from primary wire to secondary wire. The core links their magnetic fieldA region where magnets, magnetic materials or moving charges experience magnetic forces.; it is not an electrical bridge between their circuits.
Explain the induction sequence
alternating currentA flow of electric charge that repeatedly reverses direction. in the primary creates a changing magnetic fieldA region where magnets, magnetic materials or moving charges experience magnetic forces. in the core. That changing field passes through the secondary turns and induces an alternating potential differenceThe energy transferred per unit charge between two points, measured in volts. across them.
When a load completes the secondary circuit, an alternating current can flow and energyA conserved quantity transferred between stores by working, heating, electrical processes or radiation, measured in joules. is transferred to the load. A secondary voltage can still exist when the output circuit is open.
Why soft material and laminations help
A soft magnetic core magnetises and reverses readily as the primary electric currentThe amount of electric charge passing a point per unit time, measured in amperes. alternates. It provides an effective route for the changing field.
Thin insulated laminations reduce currents induced within the core and the heating they cause. They are not the wire turns. Some energyA conserved quantity transferred between stores by working, heating, electrical processes or radiation, measured in joules. is still dissipated in real windings and cores, so efficiencyThe fraction of total energy input transferred usefully, also equal to useful power output divided by total power input. is less than 100%.
Change the voltage
More secondary turns than primary turns gives a step-up transformerA transformer with more secondary than primary turns that increases alternating voltage.. Fewer secondary turns gives a step-down transformerA transformer with fewer secondary than primary turns that reduces alternating voltage.. The ideal potential differenceThe energy transferred per unit charge between two points, measured in volts. ratio equals the turns ratio, developed in 7.19P.
The drawing uses ten primary loops and two secondary loops as symbols for 500 and 100 actual turns; each drawn loop represents 50 turns. This preserves the 5:1 ratio without pretending to draw all 600 turns.
Why steady d.c. is unsuitable
A steady direct currentA flow of electric charge that keeps the same direction. produces a steady field after switching transients have settled, so it does not continuously induce a secondary potential differenceThe energy transferred per unit charge between two points, measured in volts.. Switching d.c. on or off can produce a brief induced effect; that is not sustained transformerA device using electromagnetic induction between coils to change alternating voltage. operation.
Equations
Common misconceptions
- A transformer needs a changing magnetic field, not merely an iron core.
- Primary and secondary are separate electrical circuits.
- Laminations are not coil turns.
- Steady d.c. gives no sustained secondary induction, although switching transients can occur.
Compare transformer voltage and current ratios
Change turns and input readings, then reconcile voltage change with conserved power.
What you see
- Labelled diagrams and numerical outputs describe the same selected state.
How to use it
- Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
- Reset restores every model control to its initial value. Nothing is saved.
What it shows
- Vp/Vs=Np/Ns. For an ideal transformer, VpIp=VsIs. A larger secondary/primary turns ratio gives higher secondary voltage; at fixed power, output current falls. This supports lower-current transmission for a given power. Continuous transformation needs a changing magnetic field, so this model assumes a.c., not steady d.c.
Limits of the model
- An ideal 100%-efficient transformer operates with an alternating supply. Readings use the textbook ideal-transformer voltage/current and power relationships; waveform shape and internal losses are not modelled.
- The selected input power is maintained by adjusting the output load as needed. Changing turns at fixed input power does not keep load resistance fixed. Use the numerical turn labels; the drawn coils are not to scale.
Controls
At these settings, the turns ratio is 2. Each side’s voltage×current gives the same power before rounding. This ideal comparison does not calculate transmission-line losses or real transformer efficiency.
Predict, change and explain
At 6 V primary, 100 primary turns, 200 secondary turns and 12 W input, predict both currents and output voltage. Double secondary turns at the same input power. Explain why higher output voltage does not create extra power, and connect this to transmission at lower current.
Connect the outcome to the Physics
Vp/Vs=Np/Ns. For an ideal transformer, VpIp=VsIs. A larger secondary/primary turns ratio gives higher secondary voltage; at fixed power, output current falls. This supports lower-current transmission for a given power. Continuous transformation needs a changing magnetic field, so this model assumes a.c., not steady d.c.