Learning goals
- Read time from the timebase and horizontal divisions.
- Measure several complete cycles and calculate frequency.
- Evaluate uncertainty and distinguish frequency from amplitude.
What is being measured?
The microphone converts changing air pressureThe normal force exerted per unit area, measured in pascals. into a changing potential differenceThe energy transferred per unit charge between two points, measured in volts.. The oscilloscopeAn instrument displaying how an input voltage changes with time. plots that voltage vertically against time horizontally. A repeating pattern represents the repeating vibration of the source; it is not a picture of the path travelled by an air particle.
The periodThe time taken for one complete oscillation or repeating cycle. T is the time for one complete cycle, measured between equivalent points such as one crestA point of maximum positive displacement on a transverse wave. and the next crest. frequencyThe number of complete oscillations or wave cycles per second, measured in hertz. f is the number of cycles each second, measured in hertz (Hz). A shorter period therefore means a higher frequency.
Set up a stable trace
Connect a microphone to an oscilloscopeAn instrument displaying how an input voltage changes with time., using an amplifier if the microphone requires one. Place it near a tuning fork or a loudspeaker producing a steady tone. Keep soundA mechanical wave produced by vibrations and transmitted through a material medium. at a comfortable level, do not put a loud source close to the ear, and follow the equipment instructions.
Adjust the potential differenceThe energy transferred per unit charge between two points, measured in volts. scale so the signal is large enough to read but does not clip at the screen edges. Adjust the timebase so several complete cycles fit on the display, then adjust triggering to hold the trace steady. Record the timebase in seconds or milliseconds per horizontal division.
Keep the source frequencyThe number of complete oscillations or wave cycles per second, measured in hertz. steady while taking repeat measurements. Keep microphone position and gain unchanged when comparing amplitudeThe maximum displacement from the equilibrium position in an oscillation.; these affect the displayed voltage but do not set the frequency of a steady source. If comparing different tones, deliberately change source frequency and record the timebase for each trace.
Measure, process and conclude
Choose two matching points separated by several complete cycles. Count the intervals between crestA point of maximum positive displacement on a transverse wave., not the number of crests: four successive crests span three cycles. Record the number of horizontal divisions between your endpoints and the cycle count.
Multiply the divisions by the timebase to obtain the total time. Divide by the number of cycles to obtain T. Convert T to seconds before calculating f = 1/T. Repeat the measurement and compare the frequencyThe number of complete oscillations or wave cycles per second, measured in hertz.; for a steady tone, an average of consistent repeat values is a suitable estimate.
A waveform with a smaller periodThe time taken for one complete oscillation or repeating cycle. has a higher frequency and therefore a higher pitchThe perceived highness or lowness of a sound, determined mainly by its frequency.. A taller trace alone does not establish a higher frequency. The microphone potential differenceThe energy transferred per unit charge between two points, measured in volts. amplitudeThe maximum displacement from the equilibrium position in an oscillation. also depends on its sensitivity, gain and distanceThe length of a path travelled, without regard to direction. from the source.
Worked measurement: the illustrated trace
The timebase is 0.50 ms per division. Three complete cycles span 12.0 divisions, so their total time is 12.0 × 0.50 = 6.0 ms.
One periodThe time taken for one complete oscillation or repeating cycle. is T = 6.0 / 3 = 2.0 ms. Since 1 ms = 0.001 s, T = 0.0020 s. Therefore f = 1 / 0.0020 = 500 Hz, or 5.0 × 10² Hz to two significant figures.
The vertical amplitudeThe maximum displacement from the equilibrium position in an oscillation. is 0.40 V in this example. It is not needed for the frequencyThe number of complete oscillations or wave cycles per second, measured in hertz. calculation; the relevant measurement is the horizontal time interval.
Evaluate the method
Reading endpoints introduces uncertaintyThe estimated range around a measured value within which the true value is expected to lie.. Spanning several cycles makes a given absolute timing uncertainty a smaller fraction of the measured interval. For example, an estimated ±0.1 ms interval uncertainty is 5% of 2.0 ms, but about 1.7% of 6.0 ms.
Use a steady trigger and a readable trace, minimise background soundA mechanical wave produced by vibrations and transmitted through a material medium., and repeat measurements. Repeating can reveal random variation but does not remove a wrongly set or misread timebase. If the trace drifts, clips or contains several competing frequencyThe number of complete oscillations or wave cycles per second, measured in hertz., do not claim a precise single frequency until the source and settings have been checked.
Equations
- total time = horizontal divisions × time per division
- T = total time ÷ number of complete cycles
- f = 1 ÷ T; f in Hz, T in s
Common misconceptions
- A crest-to-trough interval is half a period, not a full period.
- Count complete intervals, not crests; four crests span three cycles.
- Convert milliseconds to seconds before taking the reciprocal.
- Trace height is voltage amplitude, not frequency.