5.26P

From sound to an oscilloscope trace

A microphone converts sound-pressure changes into a varying voltage. An oscilloscope displays that voltage against time, allowing period and signal amplitude to be measured.

Recall for 5.26P · Exam questions for 5.26P · Data Gym · Logic Lab · Simulations · Reasoning about waves, rays and sound · Maths Clinic · Period and oscilloscope timebase · Read period and amplitude from sound traces

Learning goals

  • Explain the function of the microphone and oscilloscope.
  • Identify the horizontal and vertical quantities and scales.
  • Distinguish sound oscillation from the displayed voltage-time graph.
The microphone turns vibration into voltage; the trace shows voltage against time.

Convert the signal

Changing air makes the microphone diaphragm vibrate. Its transducer produces an electrical signal that follows the ; some microphones require or amplification. The cable carries this varying signal to the .

The oscilloscope displays vertically and time horizontally. A sinusoidal trace from a pure tone is a graph of the microphone signal over time, not the shape of an air particle path and not a photograph of along a room.

The timebase sets time per division; volts per division sets voltage.

Set the display

The timebase sets seconds or milliseconds per horizontal division. The scale sets volts per vertical division. Adjust both to show several readable cycles without the signal being clipped, then use triggering to hold the trace steady.

A horizontal spacing alone is not a until it is multiplied by the timebase. A vertical height alone is not a voltage until it is multiplied by the voltage scale. Record settings whenever a trace is compared with another.

Read a model trace

In the figure, the timebase is 0.50 ms per division. One cycle spans four divisions, so T = 4 × 0.50 = 2.0 ms = 0.0020 s. Thus f = 1/T = 500 Hz.

The scale is 0.20 V per division and the is two divisions above the zero line, giving 0.40 V. Peak-to-peak height runs from to crest and is twice that amplitude, 0.80 V.

Horizontal is time, vertical is voltage: not a picture of the wave. Open full-size figure
More gain enlarges the trace but not the sound; fix the settings to compare.

What conclusions are justified?

For a steady pure tone, the trace gives the . At unchanged microphone position, gain and display settings, a stronger sound generally produces a larger .

A taller trace can also result from moving the microphone closer, increasing amplifier gain or changing the vertical scale. Those changes alone do not prove the source vibrates with a greater amplitude. Complex sounds may contain several frequencies; do not every trace into a single sine-wave model.

Equations

  • T = horizontal divisions per cycle × time per division; f = 1/T.
  • Voltage amplitude = vertical divisions from zero to crest × volts per division.

Common misconceptions

  • The vertical quantity is voltage, not air displacement.
  • A crest-to-trough interval is half a cycle.
  • Peak-to-peak voltage is twice the amplitude for a symmetric trace.
  • Changing display scale can change apparent trace size without changing the sound.