Learning goals
- Describe a safe temperature–time investigation.
- Plot measured readings with labelled axes and suitable scales.
- Explain a plateau and evaluate imperfect experimental curves.
Purpose and apparatus
The investigation checks whether temperatureA measure of how hot a system is, related to the average kinetic energy of its particles. remains approximately constant while energyA conserved quantity transferred between stores by working, heating, electrical processes or radiation, measured in joules. enters a meltingThe change of state from solid to liquid as energy is supplied. sample. Use crushed ice in a small tube or beaker, a temperature probe, stopwatch and a gently warm water bath. Support the sample and probe securely; keep the sensing part within the sample, away from the glass wall and base.
A laboratory method may instead use a technician-selected pure solidA state of matter whose closely packed particles vibrate around fixed positions, giving a fixed shape and volume. with a suitable melting pointThe temperature at which the solid and liquid phases coexist at a given pressure., or record cooling and freezingThe change of state from liquid to solid as energy is removed.. The graph must span the actual state change. Use eye protection and a supervised warm bath; avoid bare flames and sudden temperature changes that could crack glass.
Collect readings and observations
Start with the ice below its melting pointThe temperature at which the solid and liquid phases coexist at a given pressure. if the solid-warming section is required. Place the sample in the warm bath and record temperatureA measure of how hot a system is, related to the average kinetic energy of its particles. at regular intervals, such as every 30 seconds. Record elapsed time in one unit throughout. Note when liquidA state of matter with closely spaced particles moving past one another, giving a fixed volume but no fixed shape. first appears and when the last solidA state of matter whose closely packed particles vibrate around fixed positions, giving a fixed shape and volume. disappears.
Keep the amount of sample, probe position and bath conditions as consistent as practical. Stir gently once enough liquid is present, without hitting the probe or glass, to reduce temperature differences within the sample. Continue until the sample is fully liquid and its temperature has risen further. Repeat using a fresh sample under comparable conditions.
Process and interpret
Plot time on the horizontal axis and temperatureA measure of how hot a system is, related to the average kinetic energy of its particles. on the vertical axis, with units, sensible scales and the measured points shown. Draw a suitable line through the trend. The solid-warming section rises, the meltingThe change of state from solid to liquid as energy is supplied. section is nearly horizontal, and the liquid-warming section rises again.
Identify the plateau using both the curve and the observation that solidA state of matter whose closely packed particles vibrate around fixed positions, giving a fixed shape and volume. and liquidA state of matter with closely spaced particles moving past one another, giving a fixed volume but no fixed shape. coexist. During it, energyA conserved quantity transferred between stores by working, heating, electrical processes or radiation, measured in joules. changes particle interactions and arrangement while average kinetic energyThe energy associated with motion, equal to half the mass multiplied by speed squared for a moving object. stays approximately constant. A flat graph by itself could also mean a heater was switched off or the sample reached thermal equilibriumA state in which both the resultant force and the resultant moment on an object are zero., so observations of the method matter.
The graph and real limitations
It uses 0.050 kg of ice, constant net energyA conserved quantity transferred between stores by working, heating, electrical processes or radiation, measured in joules. input of 20 W and no heating of apparatus. Ice warms from −10 to 0 °C in about 0.88 min, meltingThe change of state from solid to liquid as energy is supplied. continues until about 14.79 min, and water reaches 20 °C at about 18.29 min. The long plateau is physically consistent with the energy needed to melt ice.
The warm bath does not supply constant powerThe energy transferred or work done per unit time, measured in watts. to the sample, so real slopes need not match the model. Impurities can broaden melting into a range; thermometer lag, uneven temperatureA measure of how hot a system is, related to the average kinetic energy of its particles., heat exchange and changing atmospheric pressureThe force per unit area exerted by collisions of air particles with a surface. can affect readings. A nearly horizontal region within measurement uncertaintyThe estimated range around a measured value within which the true value is expected to lie. can still support the conclusion.
Cooling reverses the energy transfer: liquidA state of matter with closely spaced particles moving past one another, giving a fixed volume but no fixed shape. can cool, freeze while energy leaves at approximately constant temperature, then the solidA state of matter whose closely packed particles vibrate around fixed positions, giving a fixed shape and volume. can cool. Real freezingThe change of state from liquid to solid as energy is removed. curves can depart from the ideal shape; record what is observed rather than altering readings.
Equations
Common misconceptions
- A plateau during melting does not mean energy input has stopped.
- A perfect horizontal line is an idealisation, not a requirement to alter real readings.
- Heating and cooling curves require evidence that the sample actually changes state.