Learning goals
- Apply the fixed-mass and constant-temperature conditions.
- Calculate final pressure or volume.
- Interpret an inverse pressure–volume graph.
Connect particles to the equation
At the same temperatureA measure of how hot a system is, related to the average kinetic energy of its particles., the average molecular kinetic energyThe energy associated with motion, equal to half the mass multiplied by speed squared for a moving object. is unchanged. Compressing a fixed amount of gasA state of matter whose widely separated particles move randomly, filling the available container. into a smaller volume increases the rate of impacts on a wall area and raises pressureThe normal force exerted per unit area, measured in pascals..
The inverse relationship means equal fractional changes run in opposite directions: halving volume doubles pressure; tripling volume divides pressure by three. The product pV stays constant.
Worked compression
A fixed gasA state of matter whose widely separated particles move randomly, filling the available container. sample at 100 kPa absolute pressurePressure measured relative to a perfect vacuum, rather than relative to atmospheric pressure. occupies 2.0 L. After slow compressionA region of a longitudinal wave where particles are closer together and pressure is higher. and return to the original temperatureA measure of how hot a system is, related to the average kinetic energy of its particles. it occupies 1.0 L. Rearrange p₂ = p₁V₁/V₂.
Substitute p₂ = 100 × 2.0/1.0 = 200 kPa. Check that p₁V₁ = 200 kPa L and p₂V₂ = 200 kPa L. Consistent paired units are sufficient for this ratio; 1 L = 0.001 m³ if SI volumes are required.
Worked expansion
If the same sample expands at constant temperatureA measure of how hot a system is, related to the average kinetic energy of its particles. until pressureThe normal force exerted per unit area, measured in pascals. is 80 kPa, V₂ = p₁V₁/p₂ = 100 × 2.0/80 = 2.5 L.
A lower pressure should accompany a larger volume under these conditions. A result below 2.0 L would contradict the expected trend and signals a rearrangement or substitution error.
Read the inverse curve
A graph of pressureThe normal force exerted per unit area, measured in pascals. p vertically against volume V horizontally is a decreasing curve, not a straight line. For the example, p = 200/V when p is in kPa and V is in L. Points at 0.5, 1.0, 2.0 and 4.0 L therefore have pressures 400, 200, 100 and 50 kPa.
The ideal relationship never reaches a finite pressure at V = 0. Do not extend a plotted curve through the origin or claim the gasA state of matter whose widely separated particles move randomly, filling the available container. can be compressed to zero volume. Real gases deviate strongly at small volumes and may condense.
Control temperature and pressure reference
Use absolute pressurePressure measured relative to a perfect vacuum, rather than relative to atmospheric pressure., not a gauge reading above atmospheric pressureThe force per unit area exerted by collisions of air particles with a surface. without conversion. Keep the system sealed so the gasA state of matter whose widely separated particles move randomly, filling the available container. amount does not change.
Rapid compressionA region of a longitudinal wave where particles are closer together and pressure is higher. heats the gas. To apply the constant-temperature equation to measured states, change the volume slowly and allow the gas to return to the controlled temperatureA measure of how hot a system is, related to the average kinetic energy of its particles..
Equations
- p₁V₁ = p₂V₂; p₂ = p₁V₁/V₂; V₂ = p₁V₁/p₂.
- Use absolute pressure and consistent units for each pair; 1 L = 10⁻³ m³.
Common misconceptions
- Inverse proportionality produces a curve on a p-against-V graph.
- The pressure-volume product is constant only with fixed gas amount and temperature.
- A rapid compression need not keep the gas temperature constant.
- Neither zero volume nor uncorrected gauge pressure belongs in this simple calculation.
Compress a gas at constant temperature
Change gas volume and predict the inverse pressure change while identifying what stays fixed.
What you see
- Labelled diagrams and numerical outputs describe the same selected state.
How to use it
- Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
- Reset restores every model control to its initial value. Nothing is saved.
What it shows
- At fixed gas mass and temperature, pV is constant. Halving volume doubles absolute pressure; doubling volume halves it. Average molecular kinetic energy stays unchanged at the same Kelvin temperature. Individual molecules still have a range of speeds.
Limits of the model
- A fixed mass of ideal gas is compared at the same 300 K temperature after each adjustment. Reference volume is 1000 cm³ at 100 kPa absolute pressure.
- The piston shows equilibrium states, not a rapid compression process. Heating/cooling needed to maintain temperature is not calculated. The curve is restricted to 200–2000 cm³ and is not extended to zero volume.
Controls
Both pressure×volume products equal 100000 kPa cm³ before rounding. The same volume units are used for both states; displayed readouts are rounded independently.
Predict, change and explain
Change volume from 1000 to 500 cm³, then to 2000 cm³. Predict both pressures and compare pV. Explain why compression alone would not justify the prediction if the final temperature were different.
Connect the outcome to the Physics
At fixed gas mass and temperature, pV is constant. Halving volume doubles absolute pressure; doubling volume halves it. Average molecular kinetic energy stays unchanged at the same Kelvin temperature. Individual molecules still have a range of speeds.