6.8

Pressure and volume at constant temperature

For a fixed mass of gas at constant temperature, absolute pressure multiplied by volume stays constant: p₁V₁ = p₂V₂.

Recall for 6.8 · Exam questions for 6.8 · Data Gym · Logic Lab · Simulations · Reasoning with gas models · Maths Clinic · Pressure and volume · Check a constant-temperature compression model

Learning goals

  • Apply the fixed-mass and constant-temperature conditions.
  • Calculate final pressure or volume.
  • Interpret an inverse pressure–volume graph.
Half the volume means twice the wall impacts, so pressure doubles and pV is constant.

Connect particles to the equation

At the same , the average molecular is unchanged. Compressing a fixed amount of into a smaller volume increases the rate of impacts on a wall area and raises .

The inverse relationship means equal fractional changes run in opposite directions: halving volume doubles pressure; tripling volume divides pressure by three. The product pV stays constant.

At constant temperature, halving volume doubles pressure: pV is constant. Open full-size figure

Worked compression

A fixed sample at 100 kPa occupies 2.0 L. After slow and return to the original it occupies 1.0 L. Rearrange p₂ = p₁V₁/V₂.

Substitute p₂ = 100 × 2.0/1.0 = 200 kPa. Check that p₁V₁ = 200 kPa L and p₂V₂ = 200 kPa L. Consistent paired units are sufficient for this ratio; 1 L = 0.001 m³ if SI volumes are required.

V₂ = p₁V₁ ÷ p₂ = 100 × 2.0 ÷ 80 = 2.5 L at constant temperature.

Worked expansion

If the same sample expands at constant until is 80 kPa, V₂ = p₁V₁/p₂ = 100 × 2.0/80 = 2.5 L.

A lower pressure should accompany a larger volume under these conditions. A result below 2.0 L would contradict the expected trend and signals a rearrangement or substitution error.

Every marked state has pV = 200 kPa L: doubling volume halves pressure.

Read the inverse curve

A graph of p vertically against volume V horizontally is a decreasing curve, not a straight line. For the example, p = 200/V when p is in kPa and V is in L. Points at 0.5, 1.0, 2.0 and 4.0 L therefore have pressures 400, 200, 100 and 50 kPa.

The ideal relationship never reaches a finite pressure at V = 0. Do not extend a plotted curve through the origin or claim the can be compressed to zero volume. Real gases deviate strongly at small volumes and may condense.

Compress slowly at constant temperature; add atmospheric pressure to gauge readings.

Control temperature and pressure reference

Use , not a gauge reading above without conversion. Keep the system sealed so the amount does not change.

Rapid heats the gas. To apply the constant-temperature equation to measured states, change the volume slowly and allow the gas to return to the controlled .

Equations

  • p₁V₁ = p₂V₂; p₂ = p₁V₁/V₂; V₂ = p₁V₁/p₂.
  • Use absolute pressure and consistent units for each pair; 1 L = 10⁻³ m³.

Common misconceptions

  • Inverse proportionality produces a curve on a p-against-V graph.
  • The pressure-volume product is constant only with fixed gas amount and temperature.
  • A rapid compression need not keep the gas temperature constant.
  • Neither zero volume nor uncorrected gauge pressure belongs in this simple calculation.
Interactive model

Compress a gas at constant temperature

Change gas volume and predict the inverse pressure change while identifying what stays fixed.

What you see
  • Labelled diagrams and numerical outputs describe the same selected state.
How to use it
  • Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
  • Reset restores every model control to its initial value. Nothing is saved.
What it shows
  • At fixed gas mass and temperature, pV is constant. Halving volume doubles absolute pressure; doubling volume halves it. Average molecular kinetic energy stays unchanged at the same Kelvin temperature. Individual molecules still have a range of speeds.
Limits of the model
  • A fixed mass of ideal gas is compared at the same 300 K temperature after each adjustment. Reference volume is 1000 cm³ at 100 kPa absolute pressure.
  • The piston shows equilibrium states, not a rapid compression process. Heating/cooling needed to maintain temperature is not calculated. The curve is restricted to 200–2000 cm³ and is not extended to zero volume.

Controls

1000 cm³
Constant-temperature piston and pressure–volume curveVolume 1000 cm³ gives absolute pressure 100 kPa. The piston moves while gas mass and final temperature stay fixed. The plotted inverse curve starts at 200 cm³; it has no plotted point at zero volume.1000 cm³300 K throughoutAbsolute pressure / kPa01002003004005000500100015002000Volume / cm³
Volume 1000 cm³ gives absolute pressure 100 kPa. The piston moves while gas mass and final temperature stay fixed. The plotted inverse curve starts at 200 cm³; it has no plotted point at zero volume.
Absolute pressure100 kPa
Pressure × volume100000 kPa cm³
Final temperature300 K

Both pressure×volume products equal 100000 kPa cm³ before rounding. The same volume units are used for both states; displayed readouts are rounded independently.

Predict, change and explain

Change volume from 1000 to 500 cm³, then to 2000 cm³. Predict both pressures and compare pV. Explain why compression alone would not justify the prediction if the final temperature were different.

Connect the outcome to the Physics

At fixed gas mass and temperature, pV is constant. Halving volume doubles absolute pressure; doubling volume halves it. Average molecular kinetic energy stays unchanged at the same Kelvin temperature. Individual molecules still have a range of speeds.