4.13P

Thermal-energy calculations: find the temperature change

Use ΔQ = mcΔT to relate a sample’s thermal-energy change to mass, specific heat capacity and temperature change.

Recall for 4.13P · Exam questions for 4.13P · Data Gym · Logic Lab · Simulations · Reasoning about matter, pressure and heating · Maths Clinic · Specific heat capacity · Find specific heat capacity from heating data

Learning goals

  • Identify quantities and units before substitution.
  • Calculate energy change and rearrange the equation.
  • State when the model applies and distinguish supplied from absorbed energy.
On cooling, ΔT and ΔQ are negative; report the energy released as a positive value.

Identify the quantities

ΔQ is the change in joules, m the in kilograms, c the in J/(kg °C), and ΔT the final minus the initial temperature in °C. The delta symbol means change. Within a single state, twice the mass or twice the temperature rise requires twice the when c is constant.

For cooling, ΔT is negative if final minus initial is used, so ΔQ is negative for energy lost by the sample. If asked for the amount of energy released, give the positive magnitude and state that energy leaves. Do not use this equation alone for energy transferred during a constant-temperature state change.

Worked energy calculation

Find the gained by 2.0 kg of water warming from 20 °C to 25 °C, with c = 4200 J/(kg °C). First ΔT = 25 − 20 = 5 °C. Then ΔQ = 2.0 × 4200 × 5 = 42 000 J = 42 kJ.

Each 1 °C increase requires 2.0 × 4200 × 1 = 8400 J. The five equal steps in the figure therefore sum to 42 000 J. Units cancel as kg × J/(kg °C) × °C = J. Using 25 instead of 5 would calculate the wrong change.

Find the temperature change first, then multiply by mc for the energy. Open full-size figure
Δθ = 9000 ÷ (0.50 × 900) = 20 °C, so the final temperature is 18 + 20 = 38 °C.

Rearrange with brackets

To find c, divide by the product mΔT: c = ΔQ/(mΔT). For 42 000 J, 2.0 kg and 5 °C, c = 42 000/(2.0 × 5) = 4200 J/(kg °C). Keep the whole product in the denominator when entering it into a calculator.

Similarly, ΔT = ΔQ/(mc) and m = ΔQ/(cΔT). A 0.50 kg aluminium sample gaining 9000 J with c = 900 J/(kg °C) rises by 9000/(0.50 × 900) = 20 °C. If it starts at 18 °C, its final is 38 °C.

Use kg and J; heat losses mean the heater must supply more than mcΔθ.

Check the model and units

Convert grams to kilograms and kilojoules to joules before substitution. A difference has the same numerical value in Celsius or , so adding 273 to a difference is incorrect. Retain intermediate calculator values and round the final answer to suitable .

The calculated ΔQ is gained by the sample. A heater may need to supply more because its container and surroundings also gain energy. is treated as approximately constant and no change of state occurs over the calculation interval.

Equations

  • ΔQ = mcΔT
  • c = ΔQ/(mΔT); ΔT = ΔQ/(mc); m = ΔQ/(cΔT)

Common misconceptions

  • Use a temperature change, not the final temperature.
  • The product mc has units J/°C; multiplying by a temperature change gives energy in J.
  • A zero temperature change during melting does not mean zero energy transfer; this equation does not account for the state change.
Interactive model

Predict a temperature rise from transferred energy

Change mass, specific heat capacity, heater power and duration to predict a temperature–time graph.

What you see
  • Labelled diagrams and numerical outputs describe the same selected state.
How to use it
  • Change one control at a time, predict the outcome, then compare the readouts. All controls have keyboard-accessible sliders and step buttons.
  • Reset restores every model control to its initial value. Nothing is saved.
What it shows
  • Energy transferred=power×time. The temperature rise is energy÷(mass×specific heat capacity). More mass or greater specific heat capacity gives a smaller rise for the same input. If input also heats the container or escapes to the surroundings, using all input energy with the smaller measured rise would overestimate the sample’s specific heat capacity.
Limits of the model
  • A uniform sample starts at 20 °C with constant specific heat capacity. All input energy heats the sample; heater/container heating and losses are neglected.
  • No change of state occurs in this model. The control bounds limit the highest possible final temperature to 44 °C. A value of 4200 J/kg °C represents the course approximation for water; other settings are comparison values, not named material measurements.

Controls

1 kg
4200 J/kg °C
100 W
60 s
Ideal heating and temperature–time graphAt 60 s, energy input is 6000 J and temperature is 21.43 °C. The line projects 120 s at constant power; the dot marks the selected time. The temperature axis begins at 20 °C, not zero. No phase change or heat loss is represented.1 kg21.43 °CHeater: 100 WTemperature / °C2025303540450306090120Time / s
At 60 s, energy input is 6000 J and temperature is 21.43 °C. The line projects 120 s at constant power; the dot marks the selected time. The temperature axis begins at 20 °C, not zero. No phase change or heat loss is represented.
Energy transferred6000 J
Temperature rise1.43 °C
Final temperature21.43 °C

Temperature rise=6000÷(1×4200)=1.43 °C. Graph and readouts use the same unrounded calculation.

Predict, change and explain

For 1 kg at 4200 J/kg °C, predict the rise after a 100 W heater runs for 60 s. Halve only mass, then halve only specific heat capacity in a separate comparison. Explain why a real measured rise may be smaller than this ideal prediction.

Connect the outcome to the Physics

Energy transferred=power×time. The temperature rise is energy÷(mass×specific heat capacity). More mass or greater specific heat capacity gives a smaller rise for the same input. If input also heats the container or escapes to the surroundings, using all input energy with the smaller measured rise would overestimate the sample’s specific heat capacity.