7.8

Practical: solids and hydrogen peroxide decomposition

Compare the effect of different solids on oxygen-production rate while controlling the peroxide sample and the physical form of the solids.

LEARNING GOALS

By the end of this lesson

  • Describe a controlled method comparing selected solids.
  • Use oxygen-volume data to calculate and compare rates.
  • Evaluate whether results establish catalyst effectiveness, regeneration or a universal ranking.

What decomposes and what is measured?

Hydrogen peroxide decomposes to and oxygen: 2H₂O₂(aq) → 2H₂O(l) + O₂(g). Suitable solids, such as manganese(IV) , can accelerate this . Oxygen production over time is a measurable indicator of progress.

The solid is the proposed , while hydrogen peroxide is the . Start with a no-solid because peroxide can decompose slowly without an added catalyst. Do not assume every solid is catalytic merely because bubbles appear after it is added.

Plan a fair comparison

Use fresh equal volumes of the same hydrogen peroxide for each run, at the same measured starting temperature. Compare teacher-approved solids with controlled mass and as similar a particle-size range as practical. Keep the flask, gas syringe, mixing method, timing and connection procedure fixed.

Equal masses do not guarantee equal total surface areas: different solids have different , porosity and shape. Record preparation details and interpret any ranking as applying to the tested samples. It is not automatically a ranking of intrinsic per unit surface area or per catalytic site.

Use and a no-solid . If one run warms significantly, temperature has also changed and may contribute to its increased rate. A suitable or a sufficiently small, controlled reaction helps make the comparison more interpretable.

Hydrogen peroxide decomposes with a solid catalyst, producing oxygen collected in a supported gas syringe. A separate small sample relights a glowing splint: the test identifies oxygen. Wear eye protection. Keep flames away from oxygen.

Collect oxygen safely and consistently

Wear eye protection and use the teacher-approved peroxide and small solid quantities. Hydrogen peroxide can damage eyes and skin; may heat and foam. Avoid inhaling solid powders and follow the specific handling and disposal instructions for the chosen substances.

Collect oxygen safely and consistently (continued)

Connect the flask to a gas syringe with a freely moving plunger and enough collection capacity. Add or mix the solid using the approved method, start the timer consistently and record oxygen volume at fixed intervals. Never seal oxygen production into a rigid closed container. Keep flames away from the reaction setup because oxygen supports .

Collect oxygen safely and consistently (continued)

If a gas test is part of the approved method, a separately collected small oxygen sample relights a . Do not insert a burning splint into the reacting peroxide . A gas test identifies oxygen; it does not itself measure the .

Use a freely moving syringe and the same apparatus and timing method for each sample. Oxygen tests use a separately collected sample; keep flames away from the operating reaction.
The three mean rates are volumes divided by the same 20 s interval. The ranking applies to these prepared samples; catalytic surface area also affects rate.

Draw a supported conclusion

Compare initial gradients or over the same early interval, using repeats to judge whether differences exceed typical variation. A higher early oxygen volume supports faster under those conditions. If the same peroxide amount fully decomposes, the theoretical final oxygen amount should be the same despite different speeds.

Draw a supported conclusion (continued)

A fast oxygen evolution rate alone does not prove the solid is chemically. Recovery and reuse can provide further evidence, as discussed in 7.4. A solid that is consumed or releases its own gas may be a , so must be interpreted with the known chemistry.

Leaks, delayed sealing, foaming into tubing, syringe friction and initial dissolved gases can distort readings. Do not discard a result solely because it disagrees with a ; inspect the method and record a justified explanation or repeat.

Compare rates and a theoretical endpoint

  1. Example results over 20 s are: no-solid control 2 cm³ oxygen; solid A 18 cm³; solid B 30 cm³, with identical starting peroxide samples and otherwise controlled conditions.
  2. Mean rates are 2/20 = 0.10 cm³ s⁻¹, 18/20 = 0.90 cm³ s⁻¹ and 30/20 = 1.5 cm³ s⁻¹.
  3. Solid B gives the greatest mean rate over this interval for these prepared samples. Repeats and temperature measurements are needed to judge reliability.
  4. For a separate amount calculation, 10.0 cm³ of 0.50 mol/dm³ H₂O₂ contains 0.50 × 0.0100 = 0.0050 mol peroxide.
  5. The 2:1 equation ratio gives 0.0025 mol O₂. At the stated room-temperature-and-pressure assumption 24 dm³/mol, the theoretical oxygen volume is 0.060 dm³ = 60 cm³.
  6. A catalyst can change the time needed to approach this yield; it does not create extra peroxide. This example is not a recipe or a measured experiment.
KEY TERMS

Language that earns precision

control run
A comparison carried out without the tested addition, otherwise using the same conditions.
catalytic activity
Effectiveness in increasing reaction rate under specified conditions and a defined comparison basis.

Common misconceptions

Claim: Any solid giving bubbles must be a catalyst.

Correction: Peroxide can decompose without it, and some solids may react; compare the control and evidence for regeneration.

Claim: Equal masses give identical catalyst surface areas.

Correction: Particle size, density, porosity and shape also affect exposed area.

Claim: The fastest run must give the most final oxygen.

Correction: The same fully decomposed peroxide amount has the same theoretical oxygen yield.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

7 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

1 exam-style question with marking criteria and model responses.

Open exam questions
Data Gym

No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.

Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

1 guided model with controls, observations and investigation tasks.

Open simulations

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Recognising reversible reactions