By the end of this lesson
- Describe a method for both specified independent variables.
- Control limiting amount, gas collection, timing and temperature.
- Use gas curves to compare rate and evaluate errors.
Identify the reaction and measurement
Marble is mainly calcium carbonate. With diluteContaining a small amount of solute relative to the volume of solution. hydrochloric acidA species that donates a proton, H⁺, in an acid–base reaction. it forms calcium chloride solutionA homogeneous mixture formed when a solute dissolves in a solvent., carbon dioxideA colourless gas, CO₂, formed by complete combustion of carbon-containing fuels and detected using limewater. and waterThe compound H₂O, used as a solvent for many ionic and molecular substances.: CaCO₃(s) + 2HCl(aq) → CaCl₂(aq) + CO₂(g) + H₂O(l). The bubbling is an observationWhat is seen or measured, distinguished from the explanation inferred from it.; the equation explains which gas forms and why the solid is consumed.
Identify the reaction and measurement (continued)
A gas syringe connected to a flask can measure cumulative carbon dioxide volume. The syringe plunger must move freely and the tubing must be secure. The apparatus collects gas without allowing pressure to rise in a sealed rigid space. Use eye protection, an approved dilute acid and teacher-assessed quantities; keep faces away from the flask.
Investigate surface area
Prepare equal masses of the same marble as large chips and smaller chips. Keep acidA species that donates a proton, H⁺, in an acid–base reaction. volume and concentrationThe amount of dissolved substance per unit volume of solution., temperature, apparatus and mixing identical, with acid in excessMore of a reactant than the balanced reaction requires to consume the other reactant. so the same marble amount limits the gas yield. Record the chip-size categories rather than pretending the exact irregular surface areas are known.
Investigate surface area (continued)
Use an approved setup that allows reactantA substance consumed in a chemical reaction. to be combined after the collection apparatus is connected, or a carefully standardised mixing-and-stopper procedure. Start the timer when reaction begins and record gas volume at fixed intervals. Continue until successive readings are unchanged, checking that a stalled plunger is not creating a false plateauA region of a graph where the plotted quantity becomes approximately constant..
Use fresh reactants for repeats. Smaller chips should give a steeper initial volume curve and reach completion sooner, while the theoretical final carbon dioxideA colourless gas, CO₂, formed by complete combustion of carbon-containing fuels and detected using limewater. amount remains the same. Explain the faster rate through increased exposed area and more frequent successful collisionA collision that produces reaction because the necessary energetic and molecular conditions are met..
Investigate concentration separately
Now use the same marble mass and chip-size range for each run, with equal acidA species that donates a proton, H⁺, in an acid–base reaction. volumes at different known concentrationThe amount of dissolved substance per unit volume of solution.. Keep temperature, mixing and the collection method fixed. Prepare dilutionReduction of concentration by adding solvent while retaining the original solute amount, provided none is lost or reacts. accurately using the teacher’s method; label each concentration and do not change chip size at the same time.
Check that even the most diluteContaining a small amount of solute relative to the volume of solution. acid remains in excessMore of a reactant than the balanced reaction requires to consume the other reactant. if the final-volume comparison is meant to isolate rate. Equal volumes at different concentrations contain different amounts of acid. If dilute acid becomes limiting, its lower final volume cannot be attributed merely to slower collisions.
A higher acid concentration should give a steeper initial slope under otherwise comparable conditions. Initial-rate comparison is especially useful because reactantA substance consumed in a chemical reaction. concentrations and accessible solid area change as a run proceeds.
Process and evaluate the evidence
Plot volume in cm³ against time in seconds for each trial. Estimate initial gradients using a consistent method or compare mean rateChange in a measured reactant or product quantity divided by the time interval. over the same short interval. Report repeat variation; do not choose only the fastest run. Final volume and reaction time answer different questions.
Process and evaluate the evidence (continued)
Leaks or gas lost before connection reduce measured volume, especially in fast reactions. carbon dioxideA colourless gas, CO₂, formed by complete combustion of carbon-containing fuels and detected using limewater. dissolving in solutionA homogeneous mixture formed when a solute dissolves in a solvent., syringe friction, inconsistent chip shape, temperature drift and timing uncertainty can affect comparisons. State a plausible direction of error when the method supports it, and propose a specific improvement rather than simply “be more careful”.
The results can support how the chosen factor affects this reaction under the tested conditions. They do not prove an exact universal proportionality between concentrationThe amount of dissolved substance per unit volume of solution. or nominal chip size and rate.
Check the limiting reactant before comparing curves
- Use 0.20 g pure CaCO₃ and Aᵣ values Ca = 40, C = 12, O = 16: molar mass 100 g/mol, so n = 0.20/100 = 0.0020 mol.
- The balanced equation requires 2 × 0.0020 = 0.0040 mol HCl.
- 25.0 cm³ of 0.20 mol/dm³ acid contains 0.20 × 0.0250 = 0.0050 mol HCl, so even this dilute sample is in excess.
- Theoretical CO₂ amount is 0.0020 mol. Using the course room-temperature-and-pressure assumption 24 dm³/mol gives 0.048 dm³ = 48 cm³.
- If 0.10 mol/dm³ acid were used at the same volume, it would contain only 0.0025 mol HCl and become limiting: CO₂ = 0.00125 mol, corresponding to 30 cm³ at the same assumed conditions.
- The 48-versus-30 cm³ final-volume difference would involve different limiting amounts, so it cannot be explained as just a rate change. Actual collected volumes may also be affected by gas loss and dissolution.
Language that earns precision
- initial rate
- Reaction rate near the start, before reactant amounts have changed greatly.
- limiting reactant
- The reactant whose available amount limits how much product can form.
- excess reactant
- A reactant supplied in more than the amount needed to react with the limiting reactant.
Common misconceptions
Claim: Equal acid volumes mean equal amounts of hydrochloric acid.
Correction: Amount also depends on concentration: n = cV with compatible units.
Claim: Changing chip size and acid concentration together proves which caused the difference.
Correction: Investigate one independent variable at a time.
Claim: A gas syringe must be rigidly sealed so its plunger cannot move.
Correction: The plunger must move freely to collect gas without dangerous pressure buildup.
Continue practising
Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.
Recall practice
8 recall questions with suggested answers, explanations and self-ratings.
Open recall practiceData Gym
No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.
Maths Clinic
No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.
Logic Lab
No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.
What next?
Review the explanation and worked example, then continue through the course.
Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.