7.1

Designing investigations of reaction rate

Choose a measurable sign of reaction and a fair comparison to investigate surface area, concentration, temperature or a catalyst.

LEARNING GOALS

By the end of this lesson

  • Choose a suitable measurement of reaction progress over time.
  • Plan fair comparisons for the four specified factors.
  • Calculate a mean rate and interpret what a graph gradient measures.
Gas moves a freely sliding syringe plunger. Record calibrated volume and elapsed time; do not replace the syringe with a sealed rigid gas container.

Measure how much changes in a known time

describes how quickly are used or form. = change in a measured quantity ÷ time interval. The quantity may be gas volume in cm³, mass lost in g, or an in mol. Include both the quantity and time units: cm³ s⁻¹ and g/s measure different things and cannot be compared as bare numbers.

Measure how much changes in a known time (continued)

Choose a measurement that tracks the reaction. Gas collection can follow from marble chips and , or oxygen from hydrogen peroxide. A balance can follow mass loss if a gas escapes and other mass losses are controlled. A colour or cloudiness can compare time to a fixed visible change, but does not directly measure a gas volume.

First compare equal masses of the same solid as large and smaller pieces with identical acid, temperature and apparatus. Next change solution concentration while keeping volume, temperature and solid surface area identical. Acid is in excess in both comparisons. Smaller pieces and higher concentration give steeper product-volume curves. Key: A is the dashed curve; B is the blue solid curve; pink dots represent dissolved acid particles.

Surface area and concentration comparisons

For surface area, compare equal masses of the same marble with different chip sizes using the same volume and , temperature and apparatus. Smaller pieces expose more total surface for reaction. Collect gas readings at regular times. The same starting amount of limiting marble and acid should give the same final gas amount if collection is complete.

Surface area and concentration comparisons (continued)

For concentration, compare the same mass and chip size of marble with equal volumes of acid at different concentrations, keeping temperature and mixing fixed. Use enough acid even in the most run for marble to remain limiting if final yields are to be compared directly. Otherwise changing concentration also changes how much limiting acid is available, which can alter the final gas amount as well as the rate.

First compare the same reaction at 20 °C and 40 °C with identical amounts, concentrations and mixing. Next compare the same reaction with and without a suitable solid catalyst under otherwise identical conditions. The hotter and catalysed reactions have steeper product-mass curves. The catalyst remains at the end. Key: A is dashed; B is blue and solid; pink dots represent reactant particles and the grey block is solid catalyst.

Temperature and catalyst comparisons

For temperature, use the same amounts and , and bring them to the chosen temperature in a suitable before mixing. Keep the method, mixing and timing consistent. A cloudiness using sodium thiosulfate and is one possible teacher-controlled example: keep the total volume, depth, cross and endpoint judgement fixed, and measure the time for the cross to become obscured by sulfur.

Temperature and catalyst comparisons (continued)

That example produces , an irritant, so use only the approved small-scale method and ventilation. Temperature can also change gas volume, so raw gas volumes at different temperatures require appropriate interpretation; a difference in volume is not automatically a difference in reacted amount.

For , compare hydrogen peroxide with and without a suitable catalyst under identical starting conditions. To compare different solids, their mass and particle size as well as peroxide concentration, volume and temperature. A no-solid control gives a baseline. The practical in 7.8 explains the limits of such a comparison.

The time axis preserves the larger 30–60 s interval. Secants A and B give mean rates of 1.5 and 0.80 cm³ s⁻¹; straight lines connect the readings.

Process results and evaluate the method

Plot quantity on the vertical axis against time on the horizontal axis, with labels and units. The gradient measures rate: a steeper gas-volume curve means faster gas production at that time. A tangent estimates an instantaneous rate; a secant between two points gives an average over that interval.

Process results and evaluate the method (continued)

Repeat complete trials using fresh , identify using evidence and compare the spread before drawing a conclusion. Starting the timer late, gas leaking before sealing, inconsistent mixing or subjective can bias a comparison. A faster reaction can lose more gas during a delayed setup, so apparently lower readings need not indicate a slower chemical reaction.

Example gas-production data

Illustrative teaching values, not a recorded experiment. Intended to compare interval gradients.

Example gas-production data
Time / sGas volume / cm³
00
1018
2030
3038
6042

Read mean and changing rates from example data

  1. Suppose gas volumes at 0, 10, 20, 30 and 60 s are 0, 18, 30, 38 and 42 cm³.
  2. Mean rate over the first 20 s = (30 − 0)/20 = 1.5 cm³ s⁻¹.
  3. Mean rate from 20 to 30 s = (38 − 30)/(30 − 20) = 0.80 cm³ s⁻¹.
  4. The later rate is lower even though the total gas volume is larger. Volume is cumulative; its change per time is the rate.
  5. The small change between 30 and 60 s suggests slowing, but further readings are needed to establish a stable final volume.
KEY TERMS

Language that earns precision

mean rate
Change in a measured reactant or product quantity divided by the time interval.
control variable
A factor kept constant to make the intended comparison interpretable.
endpoint
A specified observable change used to decide when a measurement is complete.

Common misconceptions

Claim: The reaction producing most gas must be fastest.

Correction: Rate concerns change per time; final amount also depends on limiting reactant and collection.

Claim: Repeating readings on one run gives independent trials.

Correction: Independent repeats need fresh reactants and a fresh run.

Claim: A disappearing-cross time is a gas-volume rate.

Correction: It is time to a fixed optical endpoint; reciprocal time is a comparative index under controlled conditions.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

8 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

2 exam-style questions with marking criteria and model responses.

Open exam questions
Data Gym

1 data activity with worked interpretation and feedback.

Open data gym
Maths Clinic

1 mathematical skill, each with a worked example and three practice levels.

Open maths clinic
Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

2 guided models with controls, observations and investigation tasks.

Open simulations

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Factors that change reaction rate