6.21

Using physical properties to assess water purity

Measure a known water sample’s boiling or melting behaviour at a stated pressure and distinguish evidence of purity from a chemical test showing water is present.

LEARNING GOALS

By the end of this lesson

  • Describe boiling-point measurement as a physical test of a water sample’s purity.
  • Use approximately 100 °C boiling and 0 °C melting at standard atmospheric pressure as reference values.
  • Explain pressure, thermometer placement and impurity effects when interpreting a result.
  • Distinguish consistency with pure water from proof that no trace contaminant is present.

A physical test measures a property without adding a test reagent

copper(II) sulfate can show that is present, but also gives that . Purity asks whether other substances are mixed with the water. A physical test compares a property such as or with the expected behaviour of pure water.

At standard atmospheric pressure, approximately 101.3 kPa, pure water boils at about 100 °C and pure ice melts at about 0 °C. A has a characteristic sharp transition temperature at a given pressure. Temperature values without the pressure condition can lead to incorrect conclusions.

Use a fresh untreated portion of a sample already approved as water-based. Adding a chemical test reagent would change its . An arbitrary colourless unknown must not be heated just to see whether it boils at 100 °C: it could be a flammable or harmful liquid.

An immersed sensing tip must stay clear of the vessel base and sides. Use fresh approved water-based sample, steady boiling, an open vessel, stated pressure and instrument uncertainty; guard against steam and hot glass.

Measure the temperature of the boiling liquid

Place a small suitable volume of the approved sample in a clean heat-resistant vessel. Set up a thermometer or temperature probe with its sensing part immersed in the liquid, clear of the vessel bottom and sides, so that it measures the liquid rather than the hot glass. Use a probe with a suitable range and readable resolution around 100 °C.

Measure the temperature of the boiling liquid (continued)

Heat gently using the teacher-approved arrangement, for example a controlled hotplate, and record temperatures as the liquid approaches steady . Observe sustained boiling throughout the liquid rather than treating the first bubbles of dissolved air as the . Read the thermometer at eye level where relevant and allow the reading to stabilise.

Measure the temperature of the boiling liquid (continued)

For pure water at a steady pressure, the temperature remains approximately constant during boiling while energy the change of state. Record several readings during steady boiling, the pressure if available, and the instrument uncertainty. More heating increases the rate of boiling rather than necessarily raising the boiling temperature of the remaining pure liquid.

Wear eye protection, guard against and hot glass, and never heat a closed container or boil the sample dry. If anti-bumping granules are specified, add them before heating, not to an already hot liquid. Keep electrical connections away from spills and let the apparatus cool before handling.

Readings at 101.3 kPa compare samples with a pure-water reference. A agrees within stated uncertainty; B is a salt solution whose temperature rises as water leaves. Near-reference behaviour is evidence within limits, not absolute purity or drinking safety.

Compare at the same pressure and check the instrument

occurs when a liquid’s vapour pressure equals the surrounding pressure. Lower atmospheric pressure lowers the of pure ; higher pressure raises it. Thus a sub-100 °C reading at high altitude is not automatically evidence of .

A known pure-water reference measured with the same equipment at the same local pressure is useful. If both reference and sample read low by a similar amount, investigate pressure or thermometer error before assigning the difference from 100 °C to .

Compare at the same pressure and check the instrument (continued)

A probe touching the heated vessel may give an unrepresentative reading, while insufficient immersion or a slow response can also distort the . Repeating the measurement can assess consistency, but repeated agreement does not remove a systematic calibration error. Compare differences with the uncertainty of the method.

Interpret dissolved impurities and melting behaviour

Common dissolved , such as sodium chloride, raise the of and lower its point. As water boils away from a , the remaining solution becomes more , so its temperature can increase rather than remaining at the pure-water value. These effects apply to dissolved non-volatile solutes; other contaminants can behave differently.

An alternative physical check is to measure behaviour using an approved ice sample and a temperature probe, allowing it to warm slowly and observing the transition. Pure ice melts sharply at about 0 °C at ordinary atmospheric pressure. Common dissolved depress the freezing/melting transition and can cause melting over a range rather than one sharp pure-water temperature.

Interpret dissolved impurities and melting behaviour (continued)

A freezing experiment can show supercooling, in which liquid briefly falls below its expected freezing temperature before ice forms. Do not identify the lowest transient reading as the equilibrium freezing point. A carefully observed melting transition or a controlled boiling measurement is easier to interpret than an isolated temperature number.

No simple temperature test detects every trace impurity, and some can have deceptively sharp boiling behaviour. Use a result near the expected value as evidence consistent with purity within the method’s limits, rather than proof that no other substance exists in the sample.

Keep the tested sample and the conclusion clear

The question concerns the original sample. Measuring only a separately collected can miss left in the original vessel: may purify the portion being measured. Describe which liquid was tested and do not transfer a purity conclusion from a distillate to the untreated sample.

A steady temperature close to the pure-water reference, within and at the same pressure, supports the sample behaving as pure water in this test. A clear difference or a changing boiling temperature calls for an explanation involving or experimental conditions.

A colourless appearance, a positive copper sulfate test and a near-100 °C reading answer different questions. The first is an appearance, the second detects water, and the third physical purity evidence under specified conditions. None alone certifies that a laboratory sample is safe to drink, and it must not be tasted.

Compare two approved water samples with a reference

  1. Use example readings at the same pressure, approximately 101.3 kPa, with a stated reading uncertainty of ±0.2 °C. A pure-water reference gives steady readings around 100.0 °C.
  2. During steady boiling, sample A reads 99.9, 100.0 and 100.0 °C. These are consistent with the reference within the stated uncertainty, so A behaves like pure water in this measurement.
  3. An approved salt solution B reads 102.0, 102.3 and 102.6 °C as boiling continues. The first value is 2.0 °C above the reference, much larger than the stated reading uncertainty, and the subsequent rise is consistent with increasing solute concentration as water leaves.
  4. A positive anhydrous copper(II) sulfate test on a separate portion of B would still show water present. It would not cancel the physical evidence that B is a mixture.
  5. The temperatures do not identify the salt or determine its concentration. A is not proven free of every trace contaminant, and neither sample should be tasted.
KEY TERMS

Language that earns precision

pure substance
A substance consisting of a single chemical substance rather than a mixture with other substances.
boiling point
The temperature at which a liquid boils at a specified surrounding pressure.
melting point
The temperature at which a pure solid and its liquid coexist during melting at a specified pressure.
non-volatile solute
A dissolved substance that does not appreciably enter the vapour under the conditions being considered.
measurement uncertainty
The range of doubt associated with a measured value, which limits how precisely results can be compared.

Common misconceptions

Claim: Any sample that turns anhydrous copper(II) sulfate blue is pure water.

Correction: That test detects water presence; an aqueous mixture can do the same. Purity needs different evidence.

Claim: Pure water always boils at exactly 100 °C wherever it is measured.

Correction: Its boiling point depends on pressure; about 100 °C applies at standard atmospheric pressure.

Claim: The first small bubbles prove the water has reached its boiling point.

Correction: Dissolved air can escape before boiling. Use sustained boiling and a stable representative temperature.

Claim: A repeated reading removes every possible experimental error.

Correction: Repetition can show consistency, while a shared calibration or placement error may remain.

Claim: A pure-water distillate proves that the original salt solution was pure.

Correction: Distillation can leave non-volatile solutes behind; conclusions apply to the portion actually measured.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

6 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

1 exam-style question with marking criteria and model responses.

Open exam questions
Data Gym

No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.

Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

No separate simulations activity is assigned to this page. Use the teaching, worked examples and related practice above.

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Designing investigations of reaction rate