By the end of this lesson
- Describe a reliable method for separating water-soluble inks or food colourings.
- Explain the pencil baseline, solvent level, small spots and immediate marking of the solvent front.
- Use observations, Rf calculations and repeat runs to evaluate a conclusion.
Aim, materials and safe preparation
Investigate whether selected inks or food colourings contain more than one detectable dye and compare an unknown with known dye references. Use chromatographyA separation method in which components move at different rates because they interact differently with a stationary phase and a moving phase. paper, a beaker or suitable chamber, a cover, pencil, ruler, capillary spotters, samples and a solventThe substance in which a solute dissolves. selected by the teacher. waterThe compound H₂O, used as a solvent for many ionic and molecular substances. is a useful starting solvent for water-soluble inks and food colours; permanent inks may need a different solvent.
Wear eye protection and avoid skin and eye contact with dyes and solvents. Do not taste food colourings once they are laboratory samples, and never suck liquid into a capillary. Handle glass capillaries carefully. If a flammable solvent is required, use small quantities with suitable ventilation, keep it away from flames and ignition sources, and follow the laboratory risk assessment and disposal instructions. Chromatography itself does not require heating.
Prepare small, well-labelled starting spots
Draw a straight pencil baselineThe pencil starting line on a chromatogram from which sample and solvent-front distances are measured. roughly 1–2 cm from the lower edge of the paper. Mark and label sample positions along it, leaving space between them and away from the paper edges. Pencil graphiteA carbon allotrope with layers of three-bonded atoms and delocalised electrons that conduct electricity. is suitable because it does not dissolve and travel with the solventThe substance in which a solute dissolves. in this method; an ink line could add unwanted dye spots.
Prepare small, well-labelled starting spots (continued)
Use a clean capillary or spotter for each sample to place a small spot on its marked position. Let the spot dry before adding another small drop to the same place if more colour is needed. This concentrates the sample without making a large starting patch. Handle the paper by the edges to avoid contaminationUnwanted material introduced into a sample that can alter its composition or measured result..
Develop the chromatogram
Add a shallow layer of solventThe substance in which a solute dissolves. to the chamber. Suspend the paper upright with its lower edge touching the solvent and all starting spots above the solvent surface. Keep the paper from leaning against the container wall. Cover the chamber to reduce solvent evaporationEscape of molecules from a liquid surface into the gas phase, possible below the boiling point. and keep conditions more consistent; do not disturb it while the solvent rises.
Develop the chromatogram (continued)
Solvent moves through the paper by capillary actionThe movement of a liquid through narrow spaces such as the pores in chromatography paper.. The dyes repeatedly move with the solvent and interact with the stationary phaseThe phase that stays in place and interacts differently with components during chromatography.. Different relative solubilityThe maximum mass of solute that dissolves in 100 g of a particular solvent at a given temperature. and affinityThe tendency of a component to interact with a phase; stronger stationary-phase interaction tends to slow its progress. mean that different dyes spend different proportions of time moving, so they may separate into distinct spots. The process does not separate dyes simply because some are heavier than others.
Stop, mark and record
Remove the paper before the solvent frontThe furthest position reached by the solvent at the end of the run. reaches the top. Mark the solvent front immediately in pencil because the wet boundary becomes invisible as the solventThe substance in which a solute dissolves. evaporates. Let the paper dry safely and record the number, colour and position of visible spots in each lane. Keep the baselineThe pencil starting line on a chromatogram from which sample and solvent-front distances are measured. and lane labels visible in the record.
Measure from the baseline to each spot centreThe estimated middle of a chromatographic spot, used as its measurement position. and from the baseline to the solvent front. Record both distances with units, then calculate Rf valueThe distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline. for each spot. Record the solvent, paper and other relevant conditions so the comparison can be repeated. Photographing the labelled chromatogramThe pattern of separated components produced by chromatography. or drawing it to scale preserves the pattern as well as the calculated values.
Make a supported conclusion
observationWhat is seen or measured, distinguished from the explanation inferred from it.: a green food colouring gives a yellow spot and a blue spot. Conclusion: at least two coloured componentOne of the substances present in a mixture. were resolved, so the sample is a mixtureTwo or more substances together without all their particles being chemically combined into one substance.. If their colours and Rf valueThe distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline. match known references run alongside it, this supports the presence of those reference dyes.
State the limits as well as the match. One spot does not prove purity, matching Rf values do not prove unique identity, and colourless or overlapping components may be missed. An unknown spot without a matching reference is an additional detected component, not evidence that the run has failed.
Improve reliability and diagnose problems
Keep the solventThe substance in which a solute dissolves. compositionThe identities and proportions of the components of a substance., paper type and temperature comparable when comparing samples. Use similarly small starting spots, the same baselineThe pencil starting line on a chromatogram from which sample and solvent-front distances are measured. and known reference sampleA known substance run for comparison with an unknown. on the same paper. Repeat the separation to check whether the pattern and Rf valueThe distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline. are reproducible. Use the solvent-front distance from each run rather than assuming every run travelled equally far.
A submerged baseline can release dye directly into the solvent reservoir: repeat with less solvent or a higher baseline. A large or wet starting spot can cause streaks: use a smaller spot and dry between applications. No movement may mean poor solubilityThe maximum mass of solute that dissolves in 100 g of a particular solvent at a given temperature. or strong retention: try a teacher-approved alternative solvent. If the front was not marked before drying, repeat the run rather than guessing its position.
Evaluate two example chromatography runs
- A green food colouring produces two spots. In run 1 the front travels 8.0 cm, the yellow spot 2.4 cm and the blue spot 6.0 cm.
- Run 1: yellow Rf = 2.4/8.0 = 0.30; blue Rf = 6.0/8.0 = 0.75.
- In run 2, using the same solvent, paper and comparable temperature, the front travels 6.0 cm, yellow 1.8 cm and blue 4.5 cm.
- Run 2: yellow Rf = 1.8/6.0 = 0.30; blue Rf = 4.5/6.0 = 0.75. The ratios agree even though the raw travel distances differ.
- Known yellow and blue reference dyes run alongside the sample give matching colours and Rf values. The repeat results support the presence of these two dyes.
- Conclusion: the colouring contains at least two detectable components. Agreement in these example repeats supports reproducibility but does not establish absolute purity, exact composition or zero measurement uncertainty.
Language that earns precision
- capillary action
- The movement of a liquid through narrow spaces such as the pores in chromatography paper.
- development
- The stage in which solvent travels through the paper and separates sample components.
- repeat run
- A new separation used to check whether the observed pattern and calculated values are reproducible.
- controlled condition
- A condition kept comparable so that sample comparisons remain meaningful.
Common misconceptions
Claim: Use ink for a dark, easy-to-see baseline.
Correction: Use pencil; ink may dissolve and add extra components to the chromatogram.
Claim: A bigger starting spot always gives a better result.
Correction: A large spot can spread and overlap. Apply small drops and dry between them if more sample is needed.
Claim: Wait until the paper is dry before marking the solvent front.
Correction: Mark it immediately on removal while the wet boundary is still visible.
Claim: The dye travelling furthest must have the smallest particles.
Correction: Movement depends on relative solubility and interactions with the stationary phase, not a simple ranking of particle size or mass.
Continue practising
Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.
Recall practice
9 recall questions with suggested answers, explanations and self-ratings.
Open recall practiceData Gym
No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.
Maths Clinic
No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.
Logic Lab
No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.
What next?
Review the explanation and worked example, then continue through the course.
Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.