By the end of this lesson
- Measure both distances from the same baseline and use the centre of a spot.
- Calculate Rf using consistent distance units and sensible precision.
- Compare Rf values only under matching conditions and draw an appropriately limited identification.
A distance ratio
Rf valueThe distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline. = distance travelled by the componentOne of the substances present in a mixture. ÷ distance travelled by the solvent frontThe furthest position reached by the solvent at the end of the run.. Both distances start at the pencil baselineThe pencil starting line on a chromatogram from which sample and solvent-front distances are measured.. Measure to the centre of the component spot and to the solvent front in that lane, following the direction of solventThe substance in which a solute dissolves. movement.
The numerator and denominator must use the same unit. Centimetres divided by centimetres, or millimetres divided by millimetres, cancel, so Rf has no unit. The distance ratio lets you compare runs of different lengths more usefully than comparing raw distances, provided the other conditions match.
Measure before the evidence disappears
Method: remove the paper before the front reaches the top and mark the front immediately in pencil, before the solventThe substance in which a solute dissolves. evaporates. Allow the paper to dry, then mark spot centreThe estimated middle of a chromatographic spot, used as its measurement position. lightly if necessary and measure from the baselineThe pencil starting line on a chromatogram from which sample and solvent-front distances are measured.. Do not measure from the bottom edge of the paper or from the top edge of a spot.
observationWhat is seen or measured, distinguished from the explanation inferred from it.: a componentOne of the substances present in a mixture. travels 3.0 cm while the solvent frontThe furthest position reached by the solvent at the end of the run. travels 5.0 cm. Calculation: Rf valueThe distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline. = 3.0 ÷ 5.0 = 0.60. Conclusion: the component travelled 60% of the solvent-front distance in this run. Rf is a ratio describing the separation, not a speed or a concentrationThe amount of dissolved substance per unit volume of solution..
Check whether the number makes sense
A spot between the baselineThe pencil starting line on a chromatogram from which sample and solvent-front distances are measured. and front has an Rf valueThe distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline. between 0 and 1. A componentOne of the substances present in a mixture. remaining at the baseline has Rf 0; one that travels with the front has a value close to 1. Values near either extreme may be less helpful for distinguishing components than clearly separated spots between the two lines.
A calculated Rf greater than 1 usually signals an inverted ratio, mismatched units, an incorrectly marked front or measurements taken from different starting positions. Keep extra digits while calculating and round the final value to match the precision of the distances. Do not report many decimal places from a broad, faint spot.
Identify with comparable references
Rf valueThe distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline. depends on the solventThe substance in which a solute dissolves., stationary phaseThe phase that stays in place and interacts differently with components during chromatography. and conditions such as temperature. A substance does not have one universal Rf value. Changing the solvent changes its solubilityThe maximum mass of solute that dissolves in 100 g of a particular solvent at a given temperature. and its relative attraction to the stationary phase, so it can travel a different fractionA group of components collected during distillation over a similar boiling range. of the front distance.
Compare an unknown with reference substances under the same conditions, ideally alongside it in the same run. Similar Rf values, together with suitable colour evidence, support an identification. Different substances may share an Rf, so the value alone is not proof. A published value obtained with a different solvent is not a valid direct match.
Allow for measurement uncertainty
A broad spot has no perfectly sharp centre and a pencil front line has finite thickness. Repeat measurements or runs can reveal variation. If the unknown and reference values differ only slightly, decide whether the difference is meaningful in view of that variation rather than inventing a universal matching tolerance.
Measure each spot against the solvent-front distance at its lane if the front is slightly uneven. A badly sloping front, streaked spot or missing front mark calls for repeating the separation. Repeating with a second suitable solventThe substance in which a solute dissolves. can help distinguish substances that overlapped in the first solvent.
Calculate two Rf values and compare references
- Example data: the solvent front is 8.0 cm above the baseline. Unknown X has a yellow spot centred at 2.4 cm and a blue spot centred at 6.0 cm.
- Yellow spot: Rf = 2.4 ÷ 8.0 = 0.30. Blue spot: Rf = 6.0 ÷ 8.0 = 0.75. Neither value has a unit.
- The same distances in millimetres give 24 ÷ 80 = 0.30 and 60 ÷ 80 = 0.75. Changing the length unit does not change the ratio.
- Under the same conditions, yellow reference A has Rf 0.30, blue reference B has Rf 0.75 and blue reference C has Rf 0.50.
- The results support A and B as components of X. C is not supported by the observed blue spot in this run. Matching values and colours are evidence, not unique proof of identity.
- As a reverse check, 0.75 × 8.0 cm = 6.0 cm, recovering the blue spot distance.
Language that earns precision
- Rf value
- The distance travelled by a component divided by the distance travelled by the solvent front, both measured from the same baseline.
- spot centre
- The estimated middle of a chromatographic spot, used as its measurement position.
- dimensionless
- Having no unit; for Rf, identical distance units cancel.
- affinity
- The tendency of a component to interact with a phase; stronger stationary-phase interaction tends to slow its progress.
Common misconceptions
Claim: Rf is the distance travelled by the solvent divided by the spot distance.
Correction: Put the component distance in the numerator and the solvent-front distance in the denominator.
Claim: Rf has units of centimetres.
Correction: It is a ratio of two lengths in the same unit, so it has no unit.
Claim: Each substance has a fixed Rf in every solvent.
Correction: Rf is meaningful only with specified solvent, stationary phase and conditions.
Claim: An exact numerical match proves identity.
Correction: Different substances can have the same Rf; agreement supports identification but does not prove it.
Continue practising
Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.
Recall practice
7 recall questions with suggested answers, explanations and self-ratings.
Open recall practiceData Gym
No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.
Maths Clinic
No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.
Logic Lab
No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.
What next?
Review the explanation and worked example, then continue through the course.
Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.