6.14

Practical: measuring the oxygen fraction of air

Plan and evaluate a damp-iron oxygen-removal investigation, calculating an approximate percentage and identifying the limits of its evidence.

LEARNING GOALS

By the end of this lesson

  • Describe a complete oxygen-removal investigation using a metal.
  • Record comparable initial and final gas volumes and calculate oxygen percentage.
  • Explain controls, endpoint checks, repeat measurements and errors.

Choose the iron method and define the measurement

The practical requirement allows a suitable metal or non-metal. This page uses damp iron wool because its reaction with oxygen produces solid rust without deliberate ignition. Lesson 6.10 also explains heated copper and a teacher-controlled phosphorus alternative; those require their own approved apparatus and precautions.

The aim is to estimate the of oxygen in a trapped air sample. Measure the initial air volume, remove oxygen by iron, then measure the remaining gas under comparable conditions. Treat the fall in gas volume as oxygen removed, while recognising small effects from vapour and dissolution of other gases.

Set up a known enclosed volume

Wear eye protection and follow the teacher’s handling procedure for iron wool and glassware. Dampen clean iron wool with and support it near the closed end of an inverted graduated tube over a water reservoir. Use enough iron to react with all expected oxygen, but do not pack the tube so tightly that air cannot contact it. The wool should be damp rather than submerged throughout.

Set up a known enclosed volume (continued)

Secure the apparatus against falling. Establish a known trapped air volume and record its value, temperature and water levels. Account for the space occupied by wool and supports when calibrating the gas volume. The should be read at eye level with precision appropriate to the graduations.

The open tube mouth stays below the reservoir water so external air cannot simply replace the trapped sample. Water provides a movable boundary; it is not a rigid sealed vessel being heated. Arrange the initial and final readings at the same temperature and with equivalent internal/external water levels, using the teacher’s approved adjustment method, so pressure differences do not dominate the result.

The tube position is adjusted to equalise internal and external water levels for each reading. The gas calibration must allow for damp wool and support volume; the wool stays above the water.

Observe until the endpoint is supported

Leave the apparatus undisturbed while rust develops and record gas volume at suitable intervals. Oxygen combines into the solid , and rises into the tube as the gas . The rate slows as accessible oxygen is removed; no universal short time guarantees completion.

Observe until the endpoint is supported (continued)

Use successive unchanged readings, iron and sufficient exposure as evidence for an . If the wool is dry, insufficient or poorly exposed, a stable-looking reading can leave oxygen unreacted. A tube arranged similarly but without reactive iron helps detect effects of changing temperature, or the setup itself.

Record the rust appearance as a and the volume readings as quantitative . The water rise alone cannot establish the identity of every remaining gas. Avoid disturbing the apparatus or introducing new air while checking it.

A similarly arranged control without reactive iron helps detect unrelated volume changes. The numerical table uses the lesson’s example fresh trials; repeat readings of one sample are not independent trials.

Process independent repeats

For each fresh sample, calculate oxygen volume as V_initial − V_final. Oxygen percentage = (V_initial − V_final)/V_initial × 100. Use the starting gas volume, not the final volume or the full capacity of an only partly filled vessel.

Repeat the whole investigation with fresh air samples and suitable fresh apparatus/ preparation. Several readings of the same sample establish its time course, not . Calculate a percentage for each trial before comparing results or finding a mean, particularly when starting volumes differ.

The conclusion should say approximately one fifth of air is oxygen if the measurements support it, not that every sample is exactly 21.000%. Include the range of repeats and relevant method limitations. Do not discard an unusual value solely because it differs from a textbook number.

Evaluate specific errors and improvements

Incomplete oxygen removal makes the decrease too small and underestimates oxygen percentage. A final sample that is warmer at the same pressure occupies more volume, also reducing the apparent decrease. Different levels create pressure differences; equalising them for comparison reduces this source of bias.

Leaks, unaccounted solid volume, and dissolution of other gases can also affect results. Their effects depend on what changes, so a generic instruction to “be more careful” is not an explanation. Name the cause and an improvement: check gas containment, calibrate the occupied volume, compare temperatures and pressures, and use fresh repeats.

This simple method estimates oxygen proportion. It does not identify the as pure nitrogen, measure every or prove a precise modern atmospheric . The uncertainty in a classroom experiment is usually larger than the trace-gas contributions being neglected.

Analyse three example fresh trials

  1. After appropriate volume corrections and matched temperatures/pressures, trial A changes from 100.0 to 79.0 cm³: (100.0 − 79.0)/100.0 × 100 = 21.0%.
  2. Trial B changes from 80.0 to 63.6 cm³: 16.4/80.0 × 100 = 20.5%.
  3. Trial C changes from 60.0 to 47.4 cm³: 12.6/60.0 × 100 = 21.0%.
  4. Mean percentage = (21.0 + 20.5 + 21.0)/3 = 20.833…%, reported as about 20.8% for these data. The repeat range is 20.5–21.0%, a width of 0.5 percentage points.
  5. These example results support oxygen being approximately one fifth of the sample. The repeat range is not a complete uncertainty calculation and cannot reveal a bias common to all three trials.
  6. Do not average the three raw volume losses and divide by 100.0 cm³: the original sample volumes were different.
KEY TERMS

Language that earns precision

endpoint evidence
Observations supporting completion, such as stable gas volume with sufficient accessible reactant.
independent repeat
A fresh execution of the experiment rather than another reading from the same sample.
meniscus
The curved liquid surface used as the reference for a volume reading.

Common misconceptions

Claim: Three readings on one tube are three separate oxygen measurements.

Correction: They track one reaction; independent repeats need fresh trapped samples and preparations.

Claim: A 100 cm³ tube always contains 100 cm³ of trapped air.

Correction: Water, wool and supports may occupy some of its space; use the actual calibrated initial gas volume.

Claim: Stop as soon as any rust appears.

Correction: Rust appearance shows reaction has begun, not that all oxygen has been removed.

Claim: A result below 21% must be changed to the accepted value.

Correction: Report the result honestly and evaluate incomplete reaction or other method errors.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

7 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

1 exam-style question with marking criteria and model responses.

Open exam questions
Data Gym

No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.

Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

1 reasoning module with worked explanations and feedback.

Open logic lab
Simulations

No separate simulations activity is assigned to this page. Use the teaching, worked examples and related practice above.

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Identifying hydrogen, oxygen, carbon dioxide, ammonia and chlorine