5.22C

Predicting products of electrolysis with inert electrodes

Use the electrolyte’s state, the presence of water, electrode material and solution concentration to explain the products in four required electrolysis examples.

LEARNING GOALS

By the end of this lesson

  • Describe an inert-electrode electrolytic cell with a negative cathode and positive anode.
  • Predict and explain the products from molten lead(II) bromide, aqueous sodium chloride, dilute sulfuric acid and aqueous copper(II) sulfate.
  • Connect observations to electrode reactions while stating the conditions and limitations of each prediction.

Set the conditions before predicting products

uses a direct-current to drive reactions at two electrodes in an . The negative terminal supplies to the , where occurs; the positive terminal withdraws electrons from the , where occurs. carry current through the electrolyte. Electrons travel through the wires and electrodes, not as a stream through the liquid.

An conducts electricity without being a in the intended model. Platinum is a useful reference material. is often used in school experiments and is treated as inert for the stated , but carbon can slowly oxidise or erode, particularly at an oxygen-producing anode. Actual electrode material must therefore be recorded; “inert” is an experimental assumption, not a claim that graphite can never react.

Set the conditions before predicting products (continued)

First distinguish from . A simple molten contains its own without . An aqueous electrolyte contains water as well as dissolved ions, so water-derived hydrogen or oxygen may form instead of a from the dissolved salt. At the cathode, Cu²⁺ can be reduced to copper, whereas Na⁺ remains in ordinary while hydrogen forms. At the anode, halide and electrode conditions affect competition between formation and oxygen evolution.

Molten lead(II) bromide: lead and bromine

This is a teacher-assessed demonstration, not a student preparation or heating recipe. Lead and its are toxic, the material can cause severe burns, and bromine vapour is toxic and corrosive. The teacher must use an appropriate fume cupboard, and approved specialist procedure; students observe at the assessed distance, with eye protection for everyone present. The teacher collection and approved disposal or reuse of lead-containing ; wash hands after any permitted handling. Do not handle the melt, collect its vapour independently or identify it by smell.

Molten lead(II) bromide: lead and bromine (continued)

Ions can move in molten lead(II) bromide. Liquid lead forms at the negative cathode and bromine vapour at the positive anode. This is a teacher demonstration in a fume cupboard; lead compounds and bromine vapour are toxic.

With separated electrodes connected to a DC , solid PbBr₂ gives no appreciable ionic current because its are fixed. Once molten, Pb²⁺ and Br⁻ ions can move. At the negative , Pb²⁺ gains to form lead: Pb²⁺ + 2e⁻ → Pb. At the positive , bromide loses electrons: 2Br⁻ → Br₂ + 2e⁻.

Molten lead(II) bromide: lead and bromine (continued)

The expected are metallic lead droplets at the cathode or collecting below it and reddish-brown bromine vapour at the anode. At the temperature of the molten , the lead is liquid and bromine is gaseous: PbBr₂(l) → Pb(l) + Br₂(g). There is no present to supply hydrogen or oxygen. The supply drives chemical ; alone supplies mobility but is not the electrode reaction.

PbBr₂(l); Graphite electrodes. Cathode: Lead, Pb(l). Anode: Bromine, Br₂(g). Teacher demonstration only. Products follow Pb²⁺ reduction and Br⁻ oxidation; molten ions can move.
Inert graphite electrodes electrolyse concentrated aqueous sodium chloride. Hydrogen forms at the negative cathode and chlorine at the positive anode. Sodium metal is not deposited. Chlorine is toxic.

Concentrated aqueous sodium chloride: hydrogen and chlorine

For sodium chloride , or , using electrodes under the usual school conditions, the expected gas is hydrogen and the principal gas is chlorine. This is an system: sodium metal is not deposited. The cathode reaction is 2H₂O + 2e⁻ → H₂ + 2OH⁻, while Na⁺ stays in solution.

Concentrated aqueous sodium chloride: hydrogen and chlorine (continued)

At the positive anode, chloride is oxidised: 2Cl⁻ → Cl₂ + 2e⁻. Bubbles appear at both electrodes, but bubbling alone does not identify either gas. Chlorine is toxic and requires teacher-controlled containment and ; it must never be sniffed. A small, appropriately contained chlorine sample bleaches damp blue , often turning it red first.

OH⁻ production makes the cathode region alkaline. With the electrode kept apart, Na⁺ and OH⁻ remain as sodium hydroxide solution. In an undivided beaker, chlorine can dissolve and react with the alkaline solution, so do not promise a pure bulk sodium hydroxide product or equal collected gas volumes. Sodium carry charge but are not discharged in this example.

NaCl(aq); Graphite electrodes. Cathode: Hydrogen, H₂(g). Anode: Chlorine, Cl₂(g), predominant. Cathode region becomes alkaline. Concentration affects anode products. Carbon may undergo side-reactions.
NaCl(aq); Suitable inert electrodes, e.g. Pt electrodes. Cathode: Hydrogen, H₂(g). Anode: Oxygen, O₂(g), favoured. Mixed anode products are possible. Conditions and electrode material matter. Do not treat dilute/concentrated as absolute.

Dilute chloride solutions require a qualified anode prediction

The label “ sodium chloride” alone does not specify every outcome. reduces chloride availability and makes oxygen production from more competitive. For a sufficiently with suitable , such as platinum, the school is hydrogen at the and oxygen as the main anode . The oxygen can be written 2H₂O → O₂ + 4H⁺ + 4e⁻.

Dilute chloride solutions require a qualified anode prediction (continued)

There is no single boundary that applies to every electrode and operating condition. Electrode material, current and chloride concentration can allow mixed chlorine and oxygen formation. State the assumed conditions and follow the information in the question. Dilution is not a safety guarantee that chlorine cannot form; any chloride still needs the teacher’s gas-risk assessment.

Platinum electrodes electrolyse water in dilute sulfuric acid. Hydrogen and oxygen collect in a 2:1 volume ratio at the same temperature and pressure. The labelled half-equations account for electron transfer.

Dilute sulfuric acid: electrolysis of water

With sulfuric and platinum electrodes, hydrogen forms at the negative and oxygen at the positive . The acid provides , making the a much better conductor. The cathode reaction is 2H⁺ + 2e⁻ → H₂; the anode reaction is 2H₂O → O₂ + 4H⁺ + 4e⁻. Sulfate is not converted into sulfur in this experiment.

Dilute sulfuric acid: electrolysis of water (continued)

After balancing and combining the , the overall reaction is 2H₂O(l) → 2H₂(g) + O₂(g). The acid is not consumed overall. Water is consumed, so the remaining acid can become more if continues. Do not equate “not consumed overall” with “unchanged ”.

Both gases are colourless. If collected separately without significant losses at the same temperature and pressure, hydrogen volume is twice oxygen volume. A teacher-approved small hydrogen sample gives a squeaky pop with a lighted splint, and oxygen relights a . Gas samples must stay separate; do not ignite a or test beside the operating cell. may be used under the classroom inert-electrode model, with the carbon-anode limitation already stated.

H₂SO₄(aq); Platinum electrodes. Cathode: Hydrogen, H₂(g). Anode: Oxygen, O₂(g). Water is consumed overall. H₂:O₂ gas volume ratio = 2:1 under the same temperature and pressure.
CuSO₄(aq); Platinum electrodes. Cathode: Copper, Cu(s). Anode: Oxygen, O₂(g). Blue colour fades as Cu²⁺ is removed. Acidity rises with inert electrodes. Using copper electrodes changes the model.

Aqueous copper(II) sulfate: copper and oxygen

For CuSO₄ with inert platinum electrodes, the expected is copper while Cu²⁺ is sufficiently available: Cu²⁺ + 2e⁻ → Cu. A reddish-brown coating forms and the cathode gains mass. At the , is oxidised to oxygen: 2H₂O → O₂ + 4H⁺ + 4e⁻. The oxygen comes from water, not from splitting sulfate into sulfur and oxygen.

Aqueous copper(II) sulfate: copper and oxygen (continued)

The is 2Cu²⁺ + 2H₂O → 2Cu + O₂ + 4H⁺. Cu²⁺ is removed without replacement from an inert anode, so the blue becomes paler as its falls. H⁺ is produced, making the solution more acidic; aqueous copper(II) sulfate can already be mildly acidic before . Sulfate remains in solution as the counter-ion.

electrodes give the same expected school products when modelled as inert, though anode wear or can affect a real gas sample. Copper electrodes would change the anode reaction because copper can dissolve, so they are not interchangeable with for this . Prolonged electrolysis after severe Cu²⁺ depletion can also change the cathode behaviour; the copper prediction refers to the stated solution while Cu²⁺ remains available.

Use observations as evidence, with controls

In an investigation, record identity, or stated , electrode material, polarity, time and at each electrode separately. Keep electrode area, spacing and immersion depth consistent when comparing suitable . Record gas-test results separately from initial bubbling, and compare initial and final solution colour against the same background.

A copper coating, a gas test and a colour change answer different questions. Bubbling does not prove oxygen; a darker electrode does not by itself establish copper; a short run may not remove enough Cu²⁺ for visible fading. Follow a teacher-approved procedure and evaluate the evidence against the stated electrode and solution conditions, rather than memorising “one metal plus one non-metal” for every electrolyte.

Link copper deposition to changes in the solution

  1. The electrolyte is aqueous CuSO₄ and both electrodes are inert platinum. Cu²⁺ remains available at the cathode throughout the example.
  2. Use Cu²⁺ + 2e⁻ → Cu twice and 2H₂O → O₂ + 4H⁺ + 4e⁻ once so four electrons cancel.
  3. The result is 2Cu²⁺ + 2H₂O → 2Cu + O₂ + 4H⁺. The total charge is +4 on each side; atoms are conserved.
  4. If an illustrative 0.010 mol of Cu²⁺ is removed in this idealised process, 0.010 mol of copper forms, with 0.0050 mol of O₂ and 0.020 mol of H⁺ produced.
  5. Expect cathode mass gain, anode oxygen, a paler blue solution and increased acidity. The numerical amounts assume only the stated electrode reactions and are not experimental measurements.
KEY TERMS

Language that earns precision

electrolysis
Chemical change driven by an electric current through an electrolyte, with reactions at the electrodes.
inert electrode
An electrode treated as conducting without participating as a reactant in the intended electrolysis reactions.
discharge
Formation of a product at an electrode by electron transfer involving an ion.
brine
A concentrated aqueous solution of sodium chloride.

Common misconceptions

Claim: Aqueous sodium chloride gives sodium metal at the cathode.

Correction: Water is reduced to hydrogen under the stated aqueous conditions; Na⁺ remains dissolved.

Claim: All sodium chloride solutions always give only chlorine at the anode.

Correction: Concentrated brine favours chlorine in the stated setup; oxygen competes more strongly on dilution, and electrode conditions matter.

Claim: Oxygen in the copper sulfate experiment is made by decomposing sulfate.

Correction: Water is oxidised at the inert anode; sulfate remains in solution.

Claim: Graphite cannot ever react because it is called inert.

Correction: Inert describes the modelled role. Real carbon anodes can oxidise or erode, affecting observations.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

11 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

7 exam-style questions with marking criteria and model responses.

Open exam questions
Data Gym

No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.

Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

1 guided model with controls, observations and investigation tasks.

Open simulations

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Writing electrolysis half-equations and identifying redox