4.8

Industrial fractional distillation of crude oil

Follow crude oil through a furnace and a fractionating column, explaining separation through boiling ranges and a temperature gradient.

LEARNING GOALS

By the end of this lesson

  • Describe heating, vaporisation, cooling and collection in an industrial column.
  • Explain why different fractions are collected at different heights.
  • Distinguish physical separation from reactions that change hydrocarbon molecules.
Crude oil is heated in a furnace so that much of it vaporises. The heated feed enters near the bottom of a fractionating column. The column is hot at the bottom and cooler at the top. Residue leaves at the base, and vapours rise past trays with bubble caps.

Heat the feed before it enters the column

is heated in a furnace so that much of it vaporises. The hot enters near the bottom of a . The largest, least may remain liquid and leave as a rather than rising through the column as vapour.

Heat the feed before it enters the column (continued)

The column has a : it is hottest near the bottom and cooler towards the top. This gradient lets different components condense in different regions. The process is industrial and continuous, with feed entering and being withdrawn; it is not a succession of separate beakers heated to one exact temperature each.

Much of the heated feed vaporises; heavy residue remains liquid. Repeated evaporation and condensation improve separation.

Rising vapours meet progressively cooler regions

As vapours rise, they cool. with higher condense in the hotter lower regions. More components with lower boiling points remain gaseous there, travel further up and condense in cooler regions. Components with the lowest boiling points leave the top as refinery gases.

Rising vapours meet progressively cooler regions (continued)

Trays and contact between rising vapour and descending liquid allow repeated and , improving separation. In the school model, describe a as condensing where the temperature is low enough for its components to become liquid. Because a fraction is a , it is collected over a rather than at one perfectly sharp boiling point.

Liquid fractions are drawn off at different levels. The familiar order from top towards bottom is refinery gases, , , , and . Bitumen is the heavy residue, not a vapour that must first reach and condense at the top.

Vaporisation overcomes intermolecular attractions between ethane molecules. The covalent C–C and C–H bonds remain intact, preserving the molecular formula and atom inventory.

Separation preserves the molecules

Vaporisation requires energy to overcome attractions between . brings molecules closer together as energy is transferred away. Neither process requires breaking the covalent C–C and C–H bonds within the molecules.

is therefore a , not a chemical reaction. A long-chain molecule collected low in the column remains a long-chain molecule. Making smaller molecules from it requires , which changes and is taught separately in lesson 4.17.

Predict collection height from boiling points

  1. Example teaching values at the same pressure: component A boils at 80 °C and component B at 250 °C. These are illustrative components, not assigned boiling points for whole commercial fractions.
  2. At a column region around 150 °C, A can remain in the rising vapour while B is below its boiling temperature and tends to condense.
  3. B is therefore collected lower down. A travels towards a cooler region before condensing.
  4. The reasoning depends on boiling temperatures and the column gradient. It does not require either molecule to break apart.
KEY TERMS

Language that earns precision

fractional distillation
Separation of a mixture into fractions using differences in boiling behaviour and repeated vaporisation and condensation.
temperature gradient
A change in temperature with position, here from the hot bottom to the cooler top of the column.
volatile
Able to vaporise readily under the stated conditions.
residue
Material remaining after the more volatile components have been removed.

Common misconceptions

Claim: The top of the column is hottest because heat rises.

Correction: The operating column is maintained hotter at the bottom and cooler at the top.

Claim: Fractions separate because heavy molecules sink through the vapour.

Correction: The key explanation is different boiling ranges and condensation at different temperatures.

Claim: The furnace breaks long hydrocarbons into short ones during distillation.

Correction: Distillation separates existing molecules; deliberate molecular splitting belongs to cracking.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

5 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

5 exam-style questions with marking criteria and model responses.

Open exam questions
Data Gym

No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.

Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

No separate simulations activity is assigned to this page. Use the teaching, worked examples and related practice above.

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: The six main crude-oil fractions and their uses