3.8

Practical: investigating temperature changes

Plan, carry out and evaluate temperature measurements for selected dissolving, neutralisation, displacement and combustion changes.

LEARNING GOALS

By the end of this lesson

  • Separate a practical method, its temperature observations and the supported conclusion.
  • Control important variables and record repeat measurements.
  • Process a temperature change and explain limitations in the energy inference.

Choose a question and a suitable scale

One investigation can ask whether a selected change is or ; another can compare energy per for specified substances. These are different questions. Comparing raw temperature rises alone is not a fair molar-energy comparison if masses, or reacting amounts differ.

Select one or more of the specified contexts with a teacher: a dissolving, an – , a metal displacement, or . Use teacher-approved small quantities and , eye protection and a local risk assessment. Avoid skin contact and follow disposal instructions; copper-containing waste is collected rather than assumed suitable for a drain.

An insulated-cup method

Place an insulating cup in a supporting beaker, fit a loose lid and position a temperature probe in the liquid without touching the base. Measure the starting or mass. Bring both to the same temperature, record readings before mixing, then add the measured second material at a recorded time. Stir gently and record temperatures at regular intervals until a clear maximum or minimum and subsequent trend are obtained.

An insulated-cup method (continued)

For dissolving, weigh the salt and check that it dissolves completely. For , measure volumes and so the reacting ratio is known. For displacement, an example is zinc with copper(II) sulfate solution: Zn(s) + CuSO₄(aq) → ZnSO₄(aq) + Cu(s). A copper deposit and fading blue solution can support , but do not substitute those for a temperature record.

Keep the cup, lid, initial temperature, liquid amount, stirring and measurement schedule consistent between comparable trials. The chosen salt or reactant can be the ; is the . Repeat with fresh materials, not simply by reading one cooling several times.

A combustion alternative

Measure a mass of in a clamped suitable metal container and record its initial temperature. Weigh the cooled burner with its cap, then heat the water while stirring. At the chosen extinguish promptly with the cap; continue gentle stirring and temperature recording to capture the maximum. After cooling, reweigh the burner with the same cap to find the mass loss. Keep the water mass, burner distance and arrangement constant in a comparison.

Use a heatproof surface, secure apparatus and keep spare away from flames. Never refill a lit or hot burner; avoid inhaling and use the school’s ventilation procedure. A shield must not starve the flame of oxygen. Hot metal and glass remain burn hazards after heating stops.

Record observations before interpreting them

Record time in s and temperature in °C with precision appropriate to the probe, along with masses, volumes, and . A maximum above the supports an change; a minimum below it supports behaviour, assuming initially equal temperatures and no other important heat source or sink.

Record observations before interpreting them (continued)

A vertical dashed marker locates mixing. Segments connect the supplied temperature readings.

Plot temperature against time to show the baseline, mixing time and subsequent change. Do not join readings into an invented sharp peak if the probe did not capture it. Where a suitable post-reaction trend is established, a justified towards the mixing time can estimate a heat-exchange correction; identify that estimate separately from measured values.

Process, repeat and evaluate

For a cup trial, calculate ΔT and then Q_ = mcΔT using the stated solution approximation. If comparing molar changes, calculate the amount that actually reacts from the balanced equation and use ΔH = −Q_solution/n. For , instead calculate Q_ using the heated water mass, and from the burner mass loss divided by fuel . Estimate ΔH = −Q_water/n_fuel under the stated heat-transfer assumptions. Report the spread of fresh trials and investigate an before deciding whether to exclude it.

A consistent result supports , not proof that all heat was captured. Heat exchange, probe lag, incomplete dissolution or reaction, and container heating can bias the estimate. Explain a specific improvement and its purpose: a lid reduces exchange and evaporation; gentle stirring reduces ; recording more frequently can help resolve a short-lived peak. None removes every limitation.

Evaluate example neutralisation repeats

  1. Three fresh trials each mix 25.0 cm³ of 1.00 mol dm⁻³ HCl with 25.0 cm³ of 1.20 mol dm⁻³ NaOH. All reactants start at 20.0 °C.
  2. Measured peaks are 25.9, 26.1 and 26.0 °C, giving rises 5.9, 6.1 and 6.0 °C. Mean rise = (5.9 + 6.1 + 6.0)/3 = 6.0 °C; range = 0.2 °C.
  3. For 50.0 g solution with c = 4.18 J g⁻¹ °C⁻¹, the individual Q_solution values are 1233.1, 1274.9 and 1254.0 J. Mean = 1254.0 J.
  4. HCl limits each trial to 0.0250 mol water formed. The mean apparent ΔH = −1.254/0.0250 = −50.16 kJ mol⁻¹, approximately −5.0 × 10¹ kJ mol⁻¹.
  5. The consistent rises support an exothermic change and repeatability under this method. The 0.2 °C range is not a complete uncertainty estimate and does not rule out shared heat loss.
  6. Use these example data to practise the method. No laboratory execution or experimentally validated reference value is claimed.
KEY TERMS

Language that earns precision

independent repeat
A fresh execution of the method with new reactants, rather than repeated readings of the same trial.
baseline
The temperature record before the investigated change begins.
anomalous result
A result inconsistent with the pattern of other results that needs investigation, not automatic deletion.

Common misconceptions

Claim: The hottest final mixture always released most energy per mole.

Correction: Compare temperature changes, measured masses, heat capacities and reacting amounts before a molar conclusion.

Claim: Take the reading several minutes later to guarantee the true peak.

Correction: A delayed reading can miss a peak because the mixture exchanges energy with the room.

Claim: A copper deposit proves how many joules were released.

Correction: It is qualitative evidence of displacement, not a measurement of heat energy.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

8 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

3 exam-style questions with marking criteria and model responses.

Open exam questions
Data Gym

1 data activity with worked interpretation and feedback.

Open data gym
Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

No separate simulations activity is assigned to this page. Use the teaching, worked examples and related practice above.

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Hydrocarbons: carbon and hydrogen only