3.2

Measuring energy changes by simple calorimetry

Choose and explain simple calorimetry methods for dissolving, neutralisation, displacement and combustion.

LEARNING GOALS

By the end of this lesson

  • Describe insulated-cup and combustion calorimetry methods.
  • Identify the measurements needed to estimate heat transferred.
  • Explain controls and major limitations instead of treating temperature rise as energy itself.

Calorimetry connects an observation to energy

estimates an energy transfer from a measured of a known quantity of material. Record the mass being warmed or cooled and its as well as temperatures. Lesson 3.3 combines these quantities in Q = mcΔT; lesson 3.4 relates the result to the amount reacting.

Use a thermometer or temperature probe with suitable range and resolution. Stir gently so the reading represents the bulk liquid, not one unusually hot or cold region. Record temperatures against time before mixing, during the change and afterwards, rather than relying on a delayed single reading.

Teacher-controlled apparatus. The cup has a loose lid and an immersed probe clear of the base. The combustion vessel is open and clamped; the shield admits air. Use local risk assessment, eye protection and a heatproof surface; never refill a hot or lit burner.

A cup for dissolving, neutralisation and displacement

Support an insulating polystyrene cup in a beaker and use a loose insulating lid with an opening for the probe. Measure the or mass, or calculate it from volume using a stated . Allow to reach the same initial temperature. Record that temperature, add the measured second reactant, replace the lid, stir gently and record the highest or lowest temperature reached.

A cup for dissolving, neutralisation and displacement (continued)

For dissolving, add a weighed amount of the chosen to measured water and ensure it dissolves. For , mix measured volumes of known-concentration and ; include both solutions in the warmed mass. For displacement, add a measured suitable metal to a known metal-salt solution and use the equation to determine the amount that can react. The procedures share a measurement idea but have different reacting amounts and completion checks.

If reactant temperatures differ appreciably, a includes simple mixing as well as the chemical change. Equilibrating them before mixing avoids that problem. Keep solution amounts, apparatus, initial temperature and stirring comparable when investigating one chosen variable.

A flame heats a measured mass of water

For simple , clamp a suitable metal container holding a known mass of above an approved burner. Measure the initial water temperature and the mass of the cooled burner with its cap before use. Heat while stirring the water gently. At the chosen extinguish promptly with the cap, then continue gentle stirring and temperature recording to capture the maximum water temperature. Allow the burner to cool and reweigh it with the same cap. The mass difference estimates the fuel used; using the same weighed assembly avoids counting a missing cap as fuel loss.

A flame heats a measured mass of water (continued)

Keep the burner-to-container distance, water mass and apparatus consistent in comparisons. A draught shield can reduce unwanted air currents without restricting oxygen . Never seal a burning fuel system. Some energy heats the container and air; and fuel can also distort the estimate. A flame experiment is therefore generally much less well insulated than a cup experiment.

What the method can establish

Insulation and a lid reduce energy exchange; they do not eliminate it. Heat loss during an trial usually reduces the measured rise. Heat gain from the room during an trial usually reduces the measured fall. An unaccounted container heat capacity also means the liquid alone does not capture the whole energy transfer.

Repeated trials reveal variation and can support a mean, but repeating a biased setup does not remove the bias. A temperature–time graph may allow an estimate back to the mixing time when a suitable cooling trend is established; do not invent a corrected reading without data. All practical work requires teacher risk assessment, eye protection and appropriate handling of hot apparatus, and chemical waste. Do not refill a hot or lit burner.

Select the measurements for two experiments

  1. Neutralisation uses 25.0 cm³ acid and 25.0 cm³ alkali, both initially at 20.0 °C, and peaks at 26.0 °C.
  2. Assuming a final solution density of 1.00 g cm⁻³ and additive volumes, the heated solution mass is 50.0 g and ΔT is +6.0 °C. Concentrations are also needed before calculating a molar enthalpy.
  3. A combustion trial warms 100 g water from 20.0 to 35.0 °C; the cooled burner mass changes from 126.42 to 125.90 g.
  4. Use 100 g and +15.0 °C for energy absorbed by water. The 0.52 g fuel loss is a different measurement, used for energy per gram or mole.
  5. Neither setup directly measures all energy transferred by the reaction; state the neglected apparatus and environmental transfers.
KEY TERMS

Language that earns precision

calorimetry
Measurement of energy transfers using thermal measurements, often a temperature change.
specific heat capacity
Energy needed to raise the temperature of unit mass of a substance by one degree.
systematic error
A consistent influence that shifts measurements away from the quantity intended.

Common misconceptions

Claim: Use just the acid mass for a neutralisation temperature rise.

Correction: The whole mixed solution changes temperature; include the alkali solution too under the stated solution approximation.

Claim: The burner mass loss is the water mass in Q = mcΔT.

Correction: The water mass gives energy absorbed. Fuel mass loss is used separately to work out energy per gram or mole of fuel.

Claim: Close repeats prove no heat was lost.

Correction: A similar heat loss can occur in every trial, so repeatability does not establish accuracy.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

8 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

6 exam-style questions with marking criteria and model responses.

Open exam questions
Data Gym

No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.

Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

No separate simulations activity is assigned to this page. Use the teaching, worked examples and related practice above.

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Calculating heat transfer with Q = mcΔT