By the end of this lesson
- Explain why a dissolved excess alkali cannot be removed by filtration.
- Use titration to establish the required acid and alkali volumes.
- Prepare, crystallise and dry a soluble salt without indicator contamination.
Why the insoluble-excess method will not work
Sodium, potassium and ammonium saltAn ionic compound formed when the replaceable hydrogen of an acid is replaced by a metal or ammonium ion. are generally solubleAble to dissolve appreciably in a specified solvent under the experimental conditions., so their corresponding soluble baseA species that accepts a proton, H⁺, in an acid–base reaction. cannot be added in excessMore of a reactant than the balanced reaction requires to consume the other reactant. and removed as an insolubleHaving such low solubility in a solvent that only a negligible amount dissolves. residueThe material left in an apparatus after another component has escaped or been removed.. If extra NaOH remains in a sodium chloride solutionA homogeneous mixture formed when a solute dissolves in a solvent., it passes through filter paper with the salt and contaminates the productA substance formed in a chemical reaction..
Instead, determine volumes that react in the required stoichiometric ratio. For sodium chloride, HCl(aq) + NaOH(aq) → NaCl(aq) + H₂O(l), so the amounts are in a 1:1 ratio. Equal volumes only work if the concentrationThe amount of dissolved substance per unit volume of solution. are equal; other acidA species that donates a proton, H⁺, in an acid–base reaction. may require a different mole ratioThe relative amounts in moles of substances given by the coefficients in a balanced equation..
A titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution. uses a measured volume of one solution and the carefully measured volume of the other needed to reach an endpointThe observed indicator change used to signal completion in a titration.. An appropriate indicator makes that endpoint visible, but the indicator itself is an impurityAn additional substance present alongside the main intended components of a material. that must be excluded from the final preparation.
Measure the neutralising volumes
Work with teacher-selected diluteContaining a small amount of solute relative to the volume of solution. solutionA homogeneous mixture formed when a solute dissolves in a solvent. and eye protection. Use a pipette with a filler, never mouth pipetting, to transfer a fixed volume of alkaliA base that dissolves in water to give an alkaline solution. into a conical flask. Rinse the pipette with that alkali beforehand so residual waterThe compound H₂O, used as a solvent for many ionic and molecular substances. does not dilute the measured sample.
Measure the neutralising volumes (continued)
Prepare a burette with the acidA species that donates a proton, H⁺, in an acid–base reaction., including the teacher’s checks for leaks and air bubbles in the tip. Rinse it with the acid first. Read the initial and final meniscusThe curved liquid surface used as the reference for a volume reading. at eye level; the titreThe volume delivered from the burette in a titration, found from final minus initial readings. is the final reading minus the initial reading, not automatically the final reading alone.
Add a few drops of a suitable indicator to the alkali. For dilute HCl and NaOH, phenolphthaleinAn indicator that is colourless below its alkaline transition range and pink above it in ordinary dilute tests. is suitable: the alkaline solution starts pink and becomes colourless near the endpointThe observed indicator change used to signal completion in a titration. as acid is added. Swirl while adding acid, then add it dropwise near the colour change.
Use a rough titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution. to locate the endpoint, then obtain closely agreeing accurate titres according to the school method. Exclude a rough or clearly overshot result from the mean. Rinsing the flask walls with distilled water does not change the amount of alkali in the flask, although it changes the solution volume, VThe final volume of solute and solvent together, used in dm³ with c in mol dm⁻³..
Repeat the preparation without indicator
Use clean apparatus to combine the same measured alkaliA base that dissolves in water to give an alkaline solution. volume with the acidA species that donates a proton, H⁺, in an acid–base reaction. volume established from the reliable titreThe volume delivered from the burette in a titration, found from final minus initial readings.. Use the same solutionA homogeneous mixture formed when a solute dissolves in a solvent. at the same concentrationThe amount of dissolved substance per unit volume of solution., but add no indicator. This produces the saltAn ionic compound formed when the replaceable hydrogen of an acid is replaced by a metal or ammonium ion. solution without introducing indicator dye.
Repeat the preparation without indicator (continued)
This is a new preparation, not an attempt to filter indicator out of the coloured titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution. mixtureTwo or more substances together without all their particles being chemically combined into one substance.. Dissolved indicator passes through ordinary filter paper. If either stock solution has changed concentration, the old volumes no longer guarantee the correct reacting amounts.
An endpointThe observed indicator change used to signal completion in a titration. is an experimental signal chosen to be close to the stoichiometric equivalence pointThe point at which the reactants have been mixed in their balanced-equation ratio. for this acid–baseA species that accepts a proton, H⁺, in an acid–base reaction. pair. Overshooting leaves excessMore of a reactant than the balanced reaction requires to consume the other reactant. acid; stopping too early leaves excess alkali. Accurate volume measurement and an appropriate indicator are therefore part of achieving purity.
Recover and dry the salt
Gently evaporate some waterThe compound H₂O, used as a solvent for many ionic and molecular substances. from the indicator-free solutionA homogeneous mixture formed when a solute dissolves in a solvent. using the teacher’s approved heating method. Avoid vigorous boilingVaporisation throughout a liquid at its boiling temperature for the prevailing pressure. and spitting. Allow crystallisationFormation of an ordered solid from a solution or melt. under suitable conditions, separate the crystals and dry them appropriately.
Sodium chloride solubilityThe maximum mass of solute that dissolves in 100 g of a particular solvent at a given temperature. changes relatively little on cooling, so sufficient water must be removed for useful crystallisation; cooling alone may give few crystals from a diluteContaining a small amount of solute relative to the volume of solution. solution. Further slow evaporationEscape of molecules from a liquid surface into the gas phase, possible below the boiling point. can produce more crystals. For a suitable rinse, use very little cold distilled water because the productA substance formed in a chemical reaction. itself is water-soluble.
Drying removes surface moistureLiquid adhering to a solid, distinct from water incorporated in a hydrate’s crystal structure.. If a different chosen saltAn ionic compound formed when the replaceable hydrogen of an acid is replaced by a metal or ammonium ion. forms a hydrate, the method must preserve its water of crystallisationWater present in a definite ratio within the crystal structure of a hydrated compound.. Do not assume that one strong-heating procedure is suitable for every sodium, potassium or ammonium salt.
Use titration evidence for an indicator-free preparation
- A fixed 25.0 cm³ portion of 0.100 mol dm⁻³ NaOH is titrated with HCl. Two accurate titres are 19.90 and 20.00 cm³ and meet the method’s agreement criterion. The rough titre is not included.
- Mean acid volume = (19.90 + 20.00) ÷ 2 = 19.95 cm³. Repeat the preparation with 25.0 cm³ of the same NaOH and 19.95 cm³ of the same HCl, without indicator.
- To check the chemistry, define n as amount in mol, c as concentration in mol dm⁻³ and V as volume in dm³. n = cV, so n(NaOH) = 0.100 × (25.0 ÷ 1000) = 0.00250 mol.
- The HCl:NaOH ratio is 1:1, so the titre contains 0.00250 mol HCl and produces approximately 0.00250 mol NaCl at the endpoint.
- Concentrate the clean salt solution and recover dry crystals. The amount actually recovered will be lower if some salt remains dissolved or is lost during handling.
Language that earns precision
- titre
- The volume delivered from the burette in a titration, found from final minus initial readings.
- endpoint
- The observed indicator change used to signal completion in a titration.
- equivalence point
- The point at which the reactants have been mixed in their balanced-equation ratio.
- concordant titres
- Accurate titration results sufficiently close together under the stated experimental criterion.
Common misconceptions
Claim: Add excess NaOH, then filter it out.
Correction: Excess NaOH is dissolved and passes through the filter; use measured reacting volumes instead.
Claim: Crystallise the indicator-containing titration mixture to obtain pure salt.
Correction: Repeat the measured reaction without indicator before recovering the product.
Claim: Equal volumes always mean exact neutralisation.
Correction: Both solution concentrations and the reaction’s mole ratio determine the required volumes.
Continue practising
Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.
Recall practice
7 recall questions with suggested answers, explanations and self-ratings.
Open recall practiceMaths Clinic
No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.
Simulations
No separate simulations activity is assigned to this page. Use the teaching, worked examples and related practice above.
What next?
Review the explanation and worked example, then continue through the course.
Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.