2.19C

Acid–alkali titration: a reliable reacting volume

Measure the volume of acid needed to react with a fixed amount of alkali, using controlled technique, a suitable indicator and concordant titres.

LEARNING GOALS

By the end of this lesson

  • Describe preparation and use of a pipette, burette and conical flask.
  • Explain the endpoint, dropwise addition and the reasons for rinsing and reading procedures.
  • Calculate titres and a mean from concordant accurate runs, excluding the rough run.
  • Recognise indicator-choice and acid-strength limits on endpoint interpretation.

What a titration measures

A finds the volume of one needed to react with a measured amount of another. A volumetric pipette delivers a fixed volume to a conical flask; a burette delivers a variable, accurately measured volume to it. The volume delivered from the burette is called the .

The method here uses teacher-provided hydrochloric in the burette and 25.0 cm³ of sodium hydroxide solution in the flask. Their equation is HCl(aq) + NaOH(aq) → NaCl(aq) + H₂O(l), with a 1:1 amount ratio. A solution of known can be used to determine the other concentration, but the focus of this point is the experimental method and reliable reacting volume.

What a titration measures (continued)

Wear eye protection, use a pipette filler, and clamp the burette securely and vertically. Fill it at a safe height below eye level, then position it for use. Never pipette by mouth. Follow the teacher’s instructions for spills, rinsings and waste; acid and can damage eyes and skin even when they look like .

After initial cleaning with deionised water, rinse the burette with its acid through the tap and tip into waste, and rinse the pipette with the sodium hydroxide it will deliver. Rinse the conical flask with deionised water only: an alkali rinse adds unmeasured reactant. After filling through a funnel, fill the tip, clear air bubbles and remove the funnel before the initial reading.

Rinse and prepare the apparatus deliberately

Clean the burette and pipette with deionised first. Then rinse the burette with a little of the it will contain, running some through the tap and tip into a waste beaker. Rinse the pipette with a little of the sodium hydroxide it will deliver. These solution rinses remove residual water that would the measured solutions and change the reacting amounts.

Rinse and prepare the apparatus deliberately (continued)

Rinse the conical flask with deionised water only. Do not rinse it with additional : an unmeasured would add extra of alkali to the measured pipette portion. A little water left in the flask changes the total volume but not the moles of alkali transferred, so it does not change the required acid amount for this .

With the burette tap closed, fill using a funnel. Run acid through the tip until it is full and free of air bubbles, then remove the funnel before taking the initial reading. A bubble disappearing during the run makes part of the apparent delivered volume fill the tip rather than enter the flask. A drop falling from a forgotten funnel can add unrecorded liquid to the burette.

A vertical clamped burette of dilute HCl has no filling funnel and a full bubble-free tip. It delivers into a pipetted 25.0 cm³ NaOH portion with phenolphthalein on a white tile.

Transfer the fixed portion and take the first reading

Use the filler to bring into the volumetric pipette and adjust the bottom of its to the calibration mark at eye level. Deliver the 25.0 cm³ portion into the conical flask, allowing a standard delivery pipette to drain as designed with its tip touching the flask wall. Do not blow out the small liquid normally retained in its tip; the pipette is calibrated with that residue. Follow the markings and instructions for the actual pipette supplied.

Transfer the fixed portion and take the first reading (continued)

Add two or three drops of : the sodium hydroxide should be pink. Place the flask on a white tile beneath the burette so a faint colour change is easier to see. Use the same small indicator quantity in repeated runs.

Transfer the fixed portion and take the first reading (continued)

Read the bottom of the clear meniscus at eye level to avoid parallax. Record the initial reading in cm³. The scale increases downwards and the initial reading need not be zero. With a school burette marked every 0.1 cm³, estimate to the nearest 0.05 cm³ and record two decimal places, for example 1.15 cm³; follow the resolution of the supplied apparatus.

The concave meniscus bottom is level with the eye at 1.15 cm³. Scale markings increase downwards, with 0.10 cm³ divisions and estimation to 0.05 cm³. Rinse the burette with its acid, pipette with its alkali and flask with water only.
In the rough run, add acid while swirling and stop at the first persistent loss of pink. For an accurate run, use a fresh pipetted portion and slow to dropwise near the rough volume. Stop at the first persistent colourless result after mixing for about 30 seconds. Read at eye level and calculate titre = final reading − initial reading.

Find a rough endpoint, then approach it carefully

First perform a rough to locate the approximate volume needed. Add while swirling the flask to mix it with the . For this indicator and direction of addition, the is the first disappearance of the pink colour that persists after thorough mixing, for example for about 30 seconds under the stated classroom protocol. Record the final reading and label this run rough.

Find a rough endpoint, then approach it carefully (continued)

For an accurate run, prepare a fresh pipetted portion with fresh indicator. Add acid while swirling, slowing down before the rough endpoint and adding it drop by drop near the colour change. Local colourless patches that disappear on swirling do not yet represent the final endpoint. Stop at the first persistent colourless result; adding extra acid after that overshoots the endpoint.

Wash any splashes on the inside flask walls down with a little deionised so that all transferred alkali can react. This does not add extra alkali. Record the final burette reading at eye level, and calculate = final reading − initial reading. Do not treat the final reading alone as the volume delivered.

The rough run is 0.00 to 25.20. Accurate readings are 0.20 to 24.80, 1.15 to 25.80 and 0.70 to 25.25 cm³. Titres 24.60, 24.65 and 24.55 meet the declared 0.10 cm³ tolerance and average 24.60 cm³.

Repeat and select concordant titres

Repeat accurate with fresh fixed portions until the agree within the tolerance specified by the task. These are . For the example below, use a declared criterion that the largest and smallest accepted titres differ by no more than 0.10 cm³; use the criterion stated in the task. Different investigations may specify a different acceptance criterion.

Repeat and select concordant titres (continued)

Exclude the rough run from the accurate mean. Record all readings honestly, including overshoots or discrepant runs; repeat when necessary and explain exclusions. Do not choose an arbitrary pair solely because it gives a desired answer. Average the concordant accurate titres, not all final burette readings and not every run regardless of quality.

Concordance indicates . It does not prove accuracy: consistently overshooting, using an unsuitable indicator, or diluting the burette can produce similar but biased titres. Good preparation and a consistent remain essential.

For strong HCl added to strong NaOH, phenolphthalein changes from pink to colourless; methyl orange changes from yellow towards orange. Stop before methyl orange becomes deeply red. Universal indicator has a broad colour sequence and is unsuitable for a precise titration endpoint here. The endpoint is the observed colour change; equivalence is the balanced reaction amount ratio. A suitable indicator changes within the sharp pH change near equivalence.

Choose an indicator for the reaction

An indicator is an observed colour change; the is the amount ratio required by the balanced reaction. A suitable indicator changes colour within the sharp change near equivalence, so the endpoint gives a close estimate of the reacting volume. The two terms do not mean exactly the same thing.

Choose an indicator for the reaction (continued)

For ordinary strong hydrochloric and strong sodium hydroxide, or can be suitable. With acid added to , phenolphthalein changes from pink to colourless; methyl orange changes from yellow towards orange at the endpoint. Use the chosen indicator’s stated endpoint and avoid adding acid until methyl orange is deeply red. ’s broad sequence of colours makes a precise endpoint difficult to judge.

The equivalence pH is approximately 7 for this strong-acid/strong-alkali example at room temperature, but neither named indicator switches exactly at pH 7. A with a strong alkali commonly needs phenolphthalein; a with a weak alkali commonly needs methyl orange. A weak-acid/weak-base combination may lack a sufficiently sharp pH change for a reliable visual endpoint. These are indicator-choice cautions, not a requirement here to calculate curves or pH logarithms.

Calculate titres from non-zero starting readings

  1. Example teaching data for 25.0 cm³ alkali portions; all burette readings are in cm³. Rough: initial 0.00, final 25.20. Accurate run 1: initial 0.20, final 24.80. Run 2: initial 1.15, final 25.80. Run 3: initial 0.70, final 25.25.
  2. Subtract initial from final for each run: rough 25.20; run 1 = 24.80 − 0.20 = 24.60; run 2 = 25.80 − 1.15 = 24.65; run 3 = 25.25 − 0.70 = 24.55 cm³.
  3. The accurate titres span 24.65 − 24.55 = 0.10 cm³, meeting the declared no-more-than-0.10 cm³ concordance criterion.
  4. Exclude the rough run. Mean accurate titre = (24.60 + 24.65 + 24.55) ÷ 3 = 73.80 ÷ 3 = 24.60 cm³.
  5. Interpretation: approximately 24.60 cm³ of this acid reaches the chosen endpoint with each 25.0 cm³ alkali portion under this procedure. The differing volumes do not alone give concentrations; the balanced equation and a known concentration would be needed for that calculation.
KEY TERMS

Language that earns precision

titration
A method of measuring a reacting solution volume by controlled addition to a measured amount of another solution.
titre
The volume delivered from a burette to reach the chosen endpoint: final reading minus initial reading.
meniscus
The curved surface of a liquid, read at its bottom for the clear aqueous solutions used here.
endpoint
The observed indicator change used to stop a titration.
equivalence point
The point at which reactants have been combined in the amount ratio required by the balanced equation.
concordant titres
Repeated accurate titre volumes that agree within a stated tolerance.

Common misconceptions

Claim: Rinse every piece of apparatus with the alkali.

Correction: Rinse the pipette with its alkali and the burette with its acid; rinse the flask with deionised water only to avoid adding unmeasured reactant.

Claim: The burette must start at zero.

Correction: Any suitable initial reading can be used; subtract it from the final reading.

Claim: Average the rough titre with every accurate run.

Correction: Exclude the rough run and use the concordant accurate titres, recording and investigating discrepancies.

Claim: A colourless phenolphthalein endpoint proves the pH is exactly 7.

Correction: The indicator changes over its own range. Its endpoint closely estimates equivalence only when the indicator is suitable for the reaction.

Claim: Matching titres guarantee the correct answer.

Correction: Repeated results can share the same systematic error; concordance establishes repeatability, not accuracy by itself.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

10 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

6 exam-style questions with marking criteria and model responses.

Open exam questions
Data Gym

1 data activity with worked interpretation and feedback.

Open data gym
Maths Clinic

1 mathematical skill, each with a worked example and three practice levels.

Open maths clinic
Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

1 guided model with controls, observations and investigation tasks.

Open simulations

What next?

Review the explanation and worked example, then continue through the course.