By the end of this lesson
- Describe preparation and use of a pipette, burette and conical flask.
- Explain the endpoint, dropwise addition and the reasons for rinsing and reading procedures.
- Calculate titres and a mean from concordant accurate runs, excluding the rough run.
- Recognise indicator-choice and acid-strength limits on endpoint interpretation.
What a titration measures
A titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution. finds the volume of one solutionA homogeneous mixture formed when a solute dissolves in a solvent. needed to react with a measured amount of another. A volumetric pipette delivers a fixed volume to a conical flask; a burette delivers a variable, accurately measured volume to it. The volume delivered from the burette is called the titreThe volume delivered from a burette to reach the chosen endpoint: final reading minus initial reading..
The method here uses teacher-provided diluteContaining a small amount of solute relative to the volume of solution. hydrochloric acidA species that donates a proton, H⁺, in an acid–base reaction. in the burette and 25.0 cm³ of sodium hydroxide solution in the flask. Their equation is HCl(aq) + NaOH(aq) → NaCl(aq) + H₂O(l), with a 1:1 amount ratio. A solution of known concentrationThe amount of dissolved substance per unit volume of solution. can be used to determine the other concentration, but the focus of this point is the experimental method and reliable reacting volume.
What a titration measures (continued)
Wear eye protection, use a pipette filler, and clamp the burette securely and vertically. Fill it at a safe height below eye level, then position it for use. Never pipette by mouth. Follow the teacher’s instructions for spills, rinsings and waste; acid and alkaliA base that dissolves in water to give an alkaline solution. can damage eyes and skin even when they look like waterThe compound H₂O, used as a solvent for many ionic and molecular substances..
Rinse and prepare the apparatus deliberately
Clean the burette and pipette with deionised waterThe compound H₂O, used as a solvent for many ionic and molecular substances. first. Then rinse the burette with a little of the acidA species that donates a proton, H⁺, in an acid–base reaction. it will contain, running some through the tap and tip into a waste beaker. Rinse the pipette with a little of the sodium hydroxide solutionA homogeneous mixture formed when a solute dissolves in a solvent. it will deliver. These solution rinses remove residual water that would diluteContaining a small amount of solute relative to the volume of solution. the measured solutions and change the reacting amounts.
Rinse and prepare the apparatus deliberately (continued)
Rinse the conical flask with deionised water only. Do not rinse it with additional alkaliA base that dissolves in water to give an alkaline solution.: an unmeasured residueThe material left in an apparatus after another component has escaped or been removed. would add extra moleThe unit mol, containing exactly 6.02214076 × 10²³ particles. of alkali to the measured pipette portion. A little water left in the flask changes the total volume but not the moles of alkali transferred, so it does not change the required acid amount for this titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution..
With the burette tap closed, fill using a funnel. Run acid through the tip until it is full and free of air bubbles, then remove the funnel before taking the initial reading. A bubble disappearing during the run makes part of the apparent delivered volume fill the tip rather than enter the flask. A drop falling from a forgotten funnel can add unrecorded liquid to the burette.
Transfer the fixed portion and take the first reading
Use the filler to bring alkaliA base that dissolves in water to give an alkaline solution. into the volumetric pipette and adjust the bottom of its meniscusThe curved surface of a liquid, read at its bottom for the clear aqueous solutions used here. to the calibration mark at eye level. Deliver the 25.0 cm³ portion into the conical flask, allowing a standard delivery pipette to drain as designed with its tip touching the flask wall. Do not blow out the small liquid residueThe material left in an apparatus after another component has escaped or been removed. normally retained in its tip; the pipette is calibrated with that residue. Follow the markings and instructions for the actual pipette supplied.
Transfer the fixed portion and take the first reading (continued)
Add two or three drops of phenolphthaleinAn indicator that is colourless below its alkaline transition range and pink above it in ordinary dilute tests.: the sodium hydroxide solutionA homogeneous mixture formed when a solute dissolves in a solvent. should be pink. Place the flask on a white tile beneath the burette so a faint colour change is easier to see. Use the same small indicator quantity in repeated runs.
Transfer the fixed portion and take the first reading (continued)
Read the bottom of the clear acidA species that donates a proton, H⁺, in an acid–base reaction. meniscus at eye level to avoid parallax. Record the initial reading in cm³. The scale increases downwards and the initial reading need not be zero. With a school burette marked every 0.1 cm³, estimate to the nearest 0.05 cm³ and record two decimal places, for example 1.15 cm³; follow the resolution of the supplied apparatus.
Find a rough endpoint, then approach it carefully
First perform a rough titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution. to locate the approximate volume needed. Add acidA species that donates a proton, H⁺, in an acid–base reaction. while swirling the flask to mix it with the alkaliA base that dissolves in water to give an alkaline solution.. For this indicator and direction of addition, the endpointThe observed indicator change used to stop a titration. is the first disappearance of the pink colour that persists after thorough mixing, for example for about 30 seconds under the stated classroom protocol. Record the final reading and label this run rough.
Find a rough endpoint, then approach it carefully (continued)
For an accurate run, prepare a fresh pipetted portion with fresh indicator. Add acid while swirling, slowing down before the rough endpoint and adding it drop by drop near the colour change. Local colourless patches that disappear on swirling do not yet represent the final endpoint. Stop at the first persistent colourless result; adding extra acid after that overshoots the endpoint.
Wash any splashes on the inside flask walls down with a little deionised waterThe compound H₂O, used as a solvent for many ionic and molecular substances. so that all transferred alkali can react. This does not add extra alkali. Record the final burette reading at eye level, and calculate titreThe volume delivered from a burette to reach the chosen endpoint: final reading minus initial reading. = final reading − initial reading. Do not treat the final reading alone as the volume delivered.
Repeat and select concordant titres
Repeat accurate titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution. with fresh fixed portions until the titreThe volume delivered from a burette to reach the chosen endpoint: final reading minus initial reading. agree within the tolerance specified by the task. These are concordant titresRepeated accurate titre volumes that agree within a stated tolerance.. For the example below, use a declared criterion that the largest and smallest accepted titres differ by no more than 0.10 cm³; use the criterion stated in the task. Different investigations may specify a different acceptance criterion.
Repeat and select concordant titres (continued)
Exclude the rough run from the accurate mean. Record all readings honestly, including overshoots or discrepant runs; repeat when necessary and explain exclusions. Do not choose an arbitrary pair solely because it gives a desired answer. Average the concordant accurate titres, not all final burette readings and not every run regardless of quality.
Concordance indicates repeatabilityCloseness of results obtained by repeating the same method under the same conditions.. It does not prove accuracy: consistently overshooting, using an unsuitable indicator, or diluting the burette solutionA homogeneous mixture formed when a solute dissolves in a solvent. can produce similar but biased titres. Good preparation and a consistent endpointThe observed indicator change used to stop a titration. remain essential.
Choose an indicator for the reaction
An indicator endpointThe observed indicator change used to stop a titration. is an observed colour change; the equivalence pointThe point at which reactants have been combined in the amount ratio required by the balanced equation. is the amount ratio required by the balanced reaction. A suitable indicator changes colour within the sharp pHA measure of acidity or alkalinity related to the hydrogen-ion concentration of an aqueous solution. change near equivalence, so the endpoint gives a close estimate of the reacting volume. The two terms do not mean exactly the same thing.
Choose an indicator for the reaction (continued)
For ordinary diluteContaining a small amount of solute relative to the volume of solution. strong hydrochloric acidA species that donates a proton, H⁺, in an acid–base reaction. and strong sodium hydroxide, phenolphthaleinAn indicator that is colourless below its alkaline transition range and pink above it in ordinary dilute tests. or methyl orangeAn indicator that changes from red to yellow across an acidic pH range, passing through orange. can be suitable. With acid added to alkaliA base that dissolves in water to give an alkaline solution., phenolphthalein changes from pink to colourless; methyl orange changes from yellow towards orange at the endpoint. Use the chosen indicator’s stated endpoint and avoid adding acid until methyl orange is deeply red. universal indicatorA mixture of indicators that produces different colours across a wide pH range.’s broad sequence of colours makes a precise endpoint difficult to judge.
The equivalence pH is approximately 7 for this strong-acid/strong-alkali example at room temperature, but neither named indicator switches exactly at pH 7. A weak acidAn acid that only partially ionises when dissolved in water. with a strong alkali commonly needs phenolphthalein; a strong acidAn acid that fully ionises in a dilute aqueous solution. with a weak alkali commonly needs methyl orange. A weak-acid/weak-base combination may lack a sufficiently sharp pH change for a reliable visual endpoint. These are indicator-choice cautions, not a requirement here to calculate titrationA method of measuring a reacting solution volume by controlled addition to a measured amount of another solution. curves or pH logarithms.
Calculate titres from non-zero starting readings
- Example teaching data for 25.0 cm³ alkali portions; all burette readings are in cm³. Rough: initial 0.00, final 25.20. Accurate run 1: initial 0.20, final 24.80. Run 2: initial 1.15, final 25.80. Run 3: initial 0.70, final 25.25.
- Subtract initial from final for each run: rough 25.20; run 1 = 24.80 − 0.20 = 24.60; run 2 = 25.80 − 1.15 = 24.65; run 3 = 25.25 − 0.70 = 24.55 cm³.
- The accurate titres span 24.65 − 24.55 = 0.10 cm³, meeting the declared no-more-than-0.10 cm³ concordance criterion.
- Exclude the rough run. Mean accurate titre = (24.60 + 24.65 + 24.55) ÷ 3 = 73.80 ÷ 3 = 24.60 cm³.
- Interpretation: approximately 24.60 cm³ of this acid reaches the chosen endpoint with each 25.0 cm³ alkali portion under this procedure. The differing volumes do not alone give concentrations; the balanced equation and a known concentration would be needed for that calculation.
Language that earns precision
- titration
- A method of measuring a reacting solution volume by controlled addition to a measured amount of another solution.
- titre
- The volume delivered from a burette to reach the chosen endpoint: final reading minus initial reading.
- meniscus
- The curved surface of a liquid, read at its bottom for the clear aqueous solutions used here.
- endpoint
- The observed indicator change used to stop a titration.
- equivalence point
- The point at which reactants have been combined in the amount ratio required by the balanced equation.
- concordant titres
- Repeated accurate titre volumes that agree within a stated tolerance.
Common misconceptions
Claim: Rinse every piece of apparatus with the alkali.
Correction: Rinse the pipette with its alkali and the burette with its acid; rinse the flask with deionised water only to avoid adding unmeasured reactant.
Claim: The burette must start at zero.
Correction: Any suitable initial reading can be used; subtract it from the final reading.
Claim: Average the rough titre with every accurate run.
Correction: Exclude the rough run and use the concordant accurate titres, recording and investigating discrepancies.
Claim: A colourless phenolphthalein endpoint proves the pH is exactly 7.
Correction: The indicator changes over its own range. Its endpoint closely estimates equivalence only when the indicator is suitable for the reaction.
Claim: Matching titres guarantee the correct answer.
Correction: Repeated results can share the same systematic error; concordance establishes repeatability, not accuracy by itself.
Continue practising
Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.
Recall practice
10 recall questions with suggested answers, explanations and self-ratings.
Open recall practiceMaths Clinic
1 mathematical skill, each with a worked example and three practice levels.
Open maths clinicLogic Lab
No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.
What next?
Review the explanation and worked example, then continue through the course.
Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.