1.9

Melting point, boiling point and purity

Use melting and boiling behaviour as evidence of purity while keeping pressure and measurement conditions in view.

LEARNING GOALS

By the end of this lesson

  • Describe the fixed melting and boiling points of a pure substance at a specified pressure.
  • Compare sharp changes of state with the temperature ranges often observed for mixtures.
  • Draw a cautious conclusion from melting or boiling measurements.

Pure substances have characteristic temperatures

At a specified pressure, a has a characteristic and . At normal atmospheric pressure, pure melts at about 0 °C and boils at about 100 °C. These values are useful reference points, not temperatures that apply at every pressure.

During a change of state at constant pressure, energy changes the arrangement and separation of particles rather than raising their average . In an ideal heating curve, temperature stays steady while the pure sample melts or boils. Before and after the change of state, further heating can raise its temperature.

The main number line uses one scale from 70 to 85 °C. A separate enlargement makes sample A’s narrow interval readable without disguising the scale change.

Mixtures often change state over a range

A may begin at one temperature and finish at a higher temperature. A dissolved commonly lowers and broadens the of a substance. During , a liquid mixture can change as its more leave more readily; its boiling temperature may therefore change.

Mixtures often change state over a range (continued)

The specification says a mixture may melt or boil over a range, not that every mixture must do so. Some mixtures can show a sharp change of state. A steady temperature is evidence consistent with purity under , but is not absolute proof that only one substance is present.

A small dry powdered sample is heated slowly in a melting-point tube. The melting range runs from the temperature at which liquid first appears to the temperature at which the sample is fully liquid. Use supervised apparatus and heat the oil bath with an electric heater.

Measure a melting range

Method: use a small, dry, finely powdered sample in a melting-point tube and a suitable supervised melting-point apparatus. Heat slowly near the expected . Record the temperature when liquid first appears and when the last solid disappears. Keep sample preparation and heating rate comparable when testing a second sample.

Measure a melting range (continued)

: a pure reference may melt over a very narrow measured interval; an impure sample may start lower and melt over a wider interval. Conclusion: a narrow interval close to the reference value supports purity. Real instruments have limited resolution and samples may not be at exactly the sensor temperature, so an experimental interval need not be precisely zero.

Interpret boiling observations fairly

Method: measure temperature during steady in suitable apparatus with a route for vapour to escape. Use the same pressure and an appropriate thermometer position for the measurement. In a , the thermometer bulb at the entrance to the condenser measures the vapour being collected; it is not simply measuring the heater temperature.

: a liquid boils steadily near its accepted value, or its measured boiling as liquid is removed. Conclusion: compare that behaviour with reference data at the same pressure. A pure liquid at lower atmospheric pressure can boil below its usual reference value; that difference alone does not show . Never seal a heated boiling apparatus.

Separate evidence from certainty

A wider can suggest , but rapid heating, a wet sample or poor thermal contact can also affect a result. Repeat under before attributing every difference to . If a sample decomposes on heating, the change observed is not a straightforward melting-point purity test.

Combining several kinds of evidence gives a stronger conclusion. For example, a narrow melting range near the reference value and a suitable can support purity more strongly than appearance alone. Each method still has limits: neither one temperature reading nor one chromatographic spot proves that no impurity exists.

Compare two example melting records

  1. A reference solid melts at 80.0 °C. Under comparable conditions, sample A first melts at 79.8 °C and is fully liquid at 80.2 °C. Sample B melts from 74.0 °C to 78.0 °C.
  2. Range width for A = 80.2 − 79.8 = 0.4 °C. Range width for B = 78.0 − 74.0 = 4.0 °C.
  3. A melts close to the reference temperature over a much narrower interval, so the evidence suggests A is purer than B.
  4. B starts melting below the reference temperature and has a broader interval, consistent with impurities.
  5. This comparison assumes similar apparatus, pressure, heating rate and dry samples. It does not identify the impurity or prove that A is completely pure.
KEY TERMS

Language that earns precision

melting point
The temperature at which solid and liquid forms of a pure substance coexist at a specified pressure.
boiling point
The temperature at which a liquid boils at a specified external pressure.
melting range
The interval from the first observed melting to the disappearance of the last solid.
impurity
An unwanted substance mixed with the substance being studied.
volatile
Readily entering the gas phase; a more volatile component tends to vaporise more readily under the same conditions.

Common misconceptions

Claim: Water always boils at 100 °C.

Correction: This is approximately true for pure water at normal atmospheric pressure. Boiling point changes with pressure.

Claim: A sample with a fixed boiling temperature is certainly pure.

Correction: It is consistent with purity, but some mixtures also boil at a constant temperature.

Claim: A measured melting range always proves contamination.

Correction: Impurities can broaden a melting range, but heating rate and measurement limitations also need consideration.

PRACTICE AREAS

Continue practising

Use recall to retrieve this learning, then apply it in exam-style questions and the related activities selected for this page.

Recall practice

5 recall questions with suggested answers, explanations and self-ratings.

Open recall practice
Exam questions

4 exam-style questions with marking criteria and model responses.

Open exam questions
Data Gym

No separate data gym activity is assigned to this page. Use the teaching, worked examples and related practice above.

Maths Clinic

No separate maths clinic activity is assigned to this page. Use the teaching, worked examples and related practice above.

Logic Lab

No separate logic lab activity is assigned to this page. Use the teaching, worked examples and related practice above.

Simulations

No separate simulations activity is assigned to this page. Use the teaching, worked examples and related practice above.

What next?

Review the explanation and worked example, then continue through the course.

Progress stays on this device. Tap again to untick. If browser storage is unavailable, changes last only for this page session. Unfinished practice areas are not counted.

Next lesson: Choosing and using separation techniques